InSTAllATIon REquIREmEnTS
Tools and Parts
Gather the required tools and parts before starting installation. 
Read and follow the instructions provided with any tools listed 
here.
Flat-blade screwdriver
 
#2 Phillips head  
 
screwdriver
Adjustable wrench that 
 
opens to 1" (25 mm) or 
hex-head socket wrench 
(for adjusting dryer feet)
Level
 
Wire stripper (direct wire 
 
installations)
Utlility knife
 
1/4" nut driver 
 
(recommended)
Vent clamps
 
Caulking gun and 
 
compound (for installing 
new exhaust vent)
Tin snips (new vent 
 
installations)
Tape measure
 
Pliers
 
Parts supplied:
Parts package is located in dryer drum. Check that all parts  
are included.
Parts needed:
Check local codes. Check existing electrical supply and venting, 
and read “Electrical Requirements” and “Venting Requirements” 
before purchasing parts.
Mobile home installations require metal exhaust system 
hardware, available for purchase from the dealer from whom you 
purchased your dryer. For further information, please reference 
the “Assistance or Service” section of the Dryer  
User Instructions.
If using a power supply cord:
Use a UL listed power supply cord kit marked for use with 
clothes dryers. The kit should contain:
A UL listed 30-amp power supply cord, rated 120/240 volt 
 
minimum. The cord should be type SRD or SRDT and be at 
least 4 ft. (1.22 m) long. The wires that connect to the dryer 
must end in ring terminals or spade terminals with upturned 
ends.
A UL listed strain relief.
 
location Requirements
You will need:
A location allowing for proper exhaust installation.  
 
See “Venting Requirements.”
A separate 30 amp circuit.
 
If you are using power supply cord, a grounded electrical 
 
outlet located within 2 ft. (610 mm) of either side of dryer.  
See “Electrical Requirements.”
A sturdy floor to support the total weight (dryer and load) 
 
of 200 lbs. (90.7 kg). The combined weight of a companion 
appliance should also be considered.
Level floor with maximum slope of 1" (25 mm) under entire 
 
dryer. (If slope is greater than 1" [25 mm], install Extended  
Dryer Feet Kit, Part Number 279810.) If not level, clothes  
may not tumble properly and automatic sensor cycles may  
not operate correctly.
Do not operate your dryer at temperatures below 45°F (7°C). At 
lower temperatures, the dryer might not shut off at the end of an 
automatic cycle. Drying times can be extended.
The dryer must not be installed or stored in an area where it will 
be exposed to water and/or weather.
Check code requirements. Some codes limit, or do not permit, 
installation of the dryer in garages, closets, mobile homes, or 
sleeping quarters. Contact your local building inspector.
4 Leveling legs