Electrolux 134709300 User Manual

Page of 26
8
MINIMUM INSTALLATION CLEARANCES - Inches (cm)
SIDES
REAR
TOP
FRONT
 Alcove
0” (0 cm) 0” (0 cm)* 0” (0 cm)
n/a
 Under-
 Counter 0” (0 cm) 0” (0 cm)* 0” (0 cm)
n/a
 Closet
0” (0 cm) 0” (0 cm)* 0” (0 cm) 1” (2.54 cm)
Installation Requirements
Clearance requirements
60 sq. in.
(387.1cm²)
3”
(7.6cm)
60 sq. in.
(387.1cm²)
3”
(7.6cm)
0”
(0cm)
0”
(0cm)
1”
(2.54cm)
0”
(0cm)
       IMPORTANT
DO NOT INSTALL YOUR DRYER:
1.  In an area exposed to dripping water or outside
weather conditions.
2.  In  an  area  where  it  will  come  in  contact  with 
curtains, drapes, or anything that will obstruct 
the flow of combustion and ventilation air.
3.  On carpet. Floor MUST be solid with a maximum
slope of 1 inch (2.54 cm).
INSTALLATION IN A RECESS OR CLOSET
1.  A dryer installed in a bedroom, bathroom, 
recess or closet, MUST be exhausted outdoors.
2.  No other fuel burning appliance shall be 
installed in the same closet as the gas dryer.
3.  Your dryer needs the space around it for proper 
ventilation.
DO NOT install your dryer in a closet with a solid 
door.
4.  Closet door ventilation required: A minimum 
of 120 square inches (774.2 cm²) of opening,
equally divided at the top and bottom of the 
door, is required. Openings should be located 
3 inches (7.6 cm) from bottom and top of door.
Openings are required to be unobstructed 
when a door is installed. A louvered door with 
equivalent air openings for the full length of the 
door is acceptable.
closet door
       NOTE
To achieve an installation with 0” (0 cm) clearance
for the back of the dryer (for other than straight
back venting), a quick-turn 90° dryer vent elbow
must be installed as described previously in this 
manual.
F
*  or other than straight back venting, a quick-turn 90° 
dryer vent elbow must be installed to achieve 0” (0 cm)
installation.