Polaroid 111523 User Manual

Page of 83
Repair Manual
Macro 5 SLR Camera
21
Operation
The following procedures sequentially detail the picture taking operation.  For a
simplified explanation of this picture taking operation refer to the flow diagrams in
Figures 2-1 and 2-2.
Camera Setup
1. Set the camera to the desired magnification.
Note: If the magnification selector is improperly set (between settings), the
camera will not function.  For detailed information on how to select
magnification, refer to the Macro 5 SLR User's Guide.
Magnification:
Lens-to-subject
Lens focal
Effective lens   Depth
distance
length
2
aperture   of field
3
0.2x (20%)
52in./130cm
221mm
f/20
10.6in./27cm
0.4x (40%)
26in./66cm
188mm
f/34
3.8in./10cm
1x (100%)
9.9in./25cm
128mm
f/47
0.86in./2.2cm
2x (200%)
4.8in./13cm
85.4mm
f/67
0.31in./0.8cm
3x (300%)
3.1in./8cm
64mm
f/100
0.20in./0.5cm
2. If applicable, plug in desired filter kit (Polarizer or Fluorescein).
Note: Use of specified filter kit is optional.  For detailed information,  refer to 
the provided Macro 5 SLR User's Guide.
Filter Kit:
Polarizer: 
Reduces reflections from flash units when taking pictures of
glossy or glass subjects.
Fluorescein:  For external ophthalmic photography includes #2A yellow 
barrier filter and #47A blue exciter filters.