Universal Viewfinder UV-1 
When using anamorphic lenses, the UV-1 allows desqueezed 
viewing of the ground glass image. This viewfinder arm 
can also be switched over to check the anamorphically 
squeezed image. 
•  To switch over the viewfinder image, turn the switching 
knob 
➪ 
photo
. The knob does not need to be unlocked.
All other operating elements are identical in function to 
those on the standard viewfinder. The anamorphic viewfinder 
can also be used together with the 235 finder extender.
Adjusting the UV-1 
Unlike the standard viewfinder, the anamorphic 
viewfinder will only provide an undistorted image in 
horizontal, locked position. The locking stops of the UV-1 
can be adjusted to an exactly horizontal position.
•  Loosen (do not remove) the two allen screws 
➪ 
photo
 
in the locking stop.
•  Move the block 
➪ 
photo
 until the viewfinder image is 
free of distortion.
•  Retighten the allen screws.
switching knob
allen screws
block