Magazine 
Cleaning the Throat Assembly
The throat assembly 
➪ 
photo
 can be disassembled for 
cleaning.
•  Loosen the three screws 
➪ 
photo
 on the throat 
assembly cover 
➪ 
photo
.
•  Remove the holder plate 
➪ 
photo
 for the loop 
protector.
•  Pull out the throat assembly cover.
•  Clean the film running surfaces 
➪ 
photo
 and guide 
rollers 
➪ 
photo
 with a brush.
•  Put the throat assembly cover back in place.
•  Replace the holder plate for the loop protector and re-
tighten the throat assembly cover with the three screws.
Setting Friction on the Shoulder Magazine
•  Swing the roller arm 
➪ 
photo
 away from the winding 
shaft until it locks in place.
•  Unscrew the three screws on the transparent tensioning 
plate 
➪ 
photo
.
•  Remove the plate.
•  Place a film core on the take-up side.
•  Place the core adapter 
➪ 
photo
 on the feed-side.
•  Place the tension measurement device 
➪ 
photo
 on the 
core adapter on the feed side.
screws
holder plate
guide rollers