Hasselblad 10026 User Manual

Page of 93
Camera body 503CW
Adjustment
June 1998
Revision 1
Calibration
On pressing the MEASURE button one of the three LED´s will light. The variable resistor
in the camera (access behind the leather beside the ISO dial) should be turned so that the
green LED lights when the MEASURE button is pressed again.
If the red LED lights, the resistor is turned anticlockwise and if the yellow LED lights, it is
turned clockwise. At least two seconds must be allowed between measurements.
Control
To ensure the ISO dial functions, the measurement should also be made for two other
ISO settings (50 and 800).  * (100 and 1600).
In each case the green LED should light when the MEASURE button is pressed.
ISO
Exposure knob
Tolerance knob
LV
50
       + 1
  1/2
15
800
  0
  1/2
12
100
  0
  1/2
15
1600
- 1
  1/2
12
5:13
Variable resistor
* From camera serial No. from 19ER18271 - See Service info No. 12/98