Sony FCB-EX11DP User Manual

Page of 49
19
Basic Functions
Spectral Sensitivity
Characteristics
Use the graph as a reference value. We can not
guaranttee these values.
This data is measured when the IR cut filter is
removed and the characteristics of the lens and optical
source characteristics are ignored.
Vibration
Specifications
Test Method (Random vibration)
• Perform the random vibration test under the
following conditions in the X, Y and Z directions for
20 minutes in each direction.
• Fix the camera at the four fixation points of the base
using M2 screws.
• The camera vibration specification is to have no
malfunction after this test.
Power spectrum density
Effective overall value
Test time
5 to 50 Hz
4.14 m
2
/s
3
{0.043 G
2
/Hz}
50 to 100 Hz
–36 dB/oct
14.3 m/s
2
{1.46 G}
20 minutes
Eclipse
When designing the housing, refer to the dimensional
allowance as shown in the figure below.
30.97˚
8.92
21.82˚
9.56