Panasonic WV-CW244F Leaflet

Page of 2
!6
!2
!4
!5
!3
!2 Dome cover
!3 Video output cable with BNC connector
Connects with the video connector of the
monitor.
!4 Camera power cable
Supplies 24 V AC or 12 V DC from an exter-
nal power source. 
!5 Heater power cable
Supplies 24 V AC from an external power
source to an optional heater.
!6 Camera mounting bracket
Only WV-CW244S (surface mount type) is
supplied with a mounting bracket for ceiling
installation.
■ Installation Plans & Preparations
● WV-CW244F
“F” stands for flash mounting. This model can be mounted on a two-gang junction box (4“ x 4“) pre-
installed in the wall or ceiling.
1. Space
Prepare a space larger than ø160 mm.
2. Junction box
Procure and install a junction box that meets the dimensions in the figure.
3. Camera Fixing Screws
Procure four screws (M4) suitable for the junction box.
4. Cable route
Cables will go behind the junction box.
5. Waterproof Process
When necessary, apply waterproof process to the camera and relevant portions.
Be sure to apply silicone rubber to the camera fixing screws in case of outdoor installation.
INSTALLATION
Camera fixing screw x 4 (procured locally)
46mm
(1-13/16")
83.5mm (3-5/16")
● WV-CW244S
“S” stands for surface mounting. This model can be installed on the surface of the wall or ceiling
using the supplied bracket.
1. Space
Prepare a space larger than ø160 mm.
2. Bracket Fixing Screws
To fix the bracket, procure four M4 screws suitable for the surface and structure of the wall/ceil-
ing.
3. Camera Fixing Screws
Four screws are supplied as standard accessories.
4. Cable route
• When routing cables through the wall/ceiling, drill a hole as shown in the figure.
• When routing cables sideway, open the sideway cable exit unscrewing the lid by use of a hexa-
gon wrench. Screw the detached lid to the cable access hole on the bottom of the bracket.
5. Waterproof Process
When necessary, apply waterproof process to the camera and relevant portions.
If you use camera fixing screws that are locally procured, be sure to apply silicone rubber to the
screws.
85 mm
(3-3/8")
85 mm
(3-3/8")
51 mm
(2")
Camera fixing screw x 4 (supplied)
Bracket fixing screw x 4
(procured locally)
Bracket center
Cable access hole
for 3/4" pipe
2nd transport 
protection screw
2. Remove the two red-colored screws provid-
ed for transport protection using a Philips
screwdriver.
■ Mounting the Camera
● Disassembly of the camera
1. Remove the dome cover by loosening three
tamper-proof screws using the supplied bit.
Color CCTV Camera
Operating Instructions
Model No.
WV-CW244F
WV-CW244S
Before attempting to connect or operate this product,
please read these instructions carefully and save this manual for future use.
N0803-1093      3TR001693BAA      Printed in Japan
PREFACE
The WV-CW244 series is a 1/3” CCD color cam-
era designed for use in a video surveillance
system. The camera features a high picture
The exclamation point within an
equilateral triangle is intended to
alert the user to the presence of
important operating and mainte-
nance (servicing) instructions in the
literature accompanying the appli-
ance.
The lightning flash with arrowhead
symbol, within an equilateral trian-
gle, is interned to alert the user to
the presence of uninsulated "dan-
gerous voltage" within the product's
enclosure that may be of sufficient
magnitude to constitute a risk of
electric shock to persons.
The serial number of this product may be found on
the top of the unit.
You should note the serial number of this unit in the
space provided and retain this instruction as a per-
manent record of your purchase to aid identification
in the event of theft.
Model No. 
Serial No. 
SA 1966
SA 1965
WARNING: To prevent fire or electric shock hazard, do not expose this appliance to rain or moisture. 
The apparatus shall not be exposed to dripping or splashing and that no objects filled with liquids, such
as vases, shall be placed on the apparatus.
CAUTION: TO REDUCE THE RISK OF ELECTRIC SHOCK,
DO NOT REMOVE COVER (OR BACK).
NO USER-SERVICEABLE PARTS INSIDE. REFER SER-
VICING TO QUALIFIED SERVICE PERSONNEL.
CAUTION
RISK OF ELECTRIC
SHOCK DO NOT OPEN
NOTE: This equipment has been tested and found
to comply with the limits for a Class A digital
device, pursuant to Part 15 of the FCC Rules.
These limits are designed to provide reasonable
protection against harmful interference when the
equipment is operated in a commercial environ-
ment. This equipment generates, uses, and can
radiate radio frequency energy and, if not installed
and used in accordance with the instruction manu-
al, may cause harmful interference to radio com-
munications.
Operation of this equipment in a residential area is
likely to cause harmful interference in which case
the user will be required to correct the interference
at his own expense.
FCC Caution: To assure continued compliance,
(example - use only shielded interface cables when
connecting to computer or peripheral devices). Any
changes or modifications not expressly approved
by the party responsible for compliance could void
the user’s authority to operate this equipment.
For U.S.A
quality thanks to the use of digital signal pro-
cessing LSIs, and easy installation. 
1. This product should be installed and con-
nected by qualified service personnel or
system installers in conformity with NEC.
2. Use a class 2 power source supplying 12 V
DC or 24 V AC.
3. To prevent fire or electric shock hazard, use
a UL listed cable (VW-1, style 1007) to con-
nect the power supply to the camera.
4. Be sure to use a ceiling board/wall having
enough strength to support this camera. 
5. Handle the camera with care.
Do not abuse the camera. Avoid striking,
shaking, etc. The camera could be dam-
aged by improper handling or storage.
6. Do not use strong or abrasive
detergents.
Use a dry cloth to clean the camera body
when dirty.
In case the dirt is hard to remove, use a
mild detergent and wipe gently. Afterwards,
wipe off the remaining detergent with a dry
cloth.
7. Clean the lens faceplate with care.
Do not clean the lens with strong or abra-
sive detergents. Use lens tissue or a cotton
tipped applicator and ethanol.
8. Never face the camera towards the sun.
Do not aim the camera at bright objects.
Whether the camera is in use or not, never
aim it at the sun or other extremely bright
objects. Otherwise, blooming or smear may
be caused.
9. Do not operate the camera beyond its
specifications.
Use the camera under conditions where
temperature is between –10 °C to +50 °C
(14 °F to 122 °F), and humidity is below
90 %. The input power source is 24 V AC or
12 V DC.
10. Use a monitor whose resolution is at least
equal to that of the camera.
PRECAUTIONS
• Mounting method: Flash mounting/WV-
CW244F, Surface mounting/WV-CW244S
• Signal processing: Automatic Light Control
(ALC), Automatic Gain Control (AGC),
Automatic Tracing White Balance (ATW),
etc.
• Synchronization: Internal, Line-Lock (only
24 V AC), and Multiplexed Vertical Drive
(VD2)
• Minimum illumination: 2.4 lx (0.24 foot-can-
dle) at WIDE
• Signal-to-noise ratio: 50 dB (Equivalent to
AGC OFF)
• Horizontal resolution: 480 TV lines
• Optional heater unit available for the cam-
era used at temperatures between –10 ˚C
and –30 ˚C (14˚F and –22˚F).
FEATURES
MAJOR OPERATING CONTROLS AND THEIR FUNCTIONS
Focus lock lever
Fixes the focus position after adjusting.
Tilting lock screw
Fixes the tilting position after adjusting.
Zoom lock lever
Fixes the zoom position after adjusting.
Panning table
Adjusts the panning angle of the camera.
Azimuth adjuster
Adjusts the azimuth angle to obtain a level
image.
Pan lock screw
Fixes the panning position after adjusting.
Heater power connector
Supplies power to the optional heater unit
when it is built in the camera. Connect here
a harness sticking out from the heater unit.
Synchronization Mode Selector
Specifies a source for synchronization.
INT: Internal 2:1 interlace.
LL: Line-lock mode driven by 24 V AC.
The default setting is INT.
Note: Do not set the switch to LL (Line-
Lock) position when supplying 12 V DC
to avoid synchronization error.
Back Light Compensation Selector
ON: Compensates the background if it is
brighter than the object.
OFF: Does not compensate.
The default setting is OFF.
!0 Aperture Level Selector
SHARP: Sharpens the image outline.
SOFT: Softens the image outline.
The default setting is SHARP.
!1 Video jack (3.5-diam. mini jack)
For connecting an LCD monitor to adjust
the camera images. Use an L-type plug to
save space.
ON
12
3
OFF
ON
LL
SYNC
INT*
OFF*
BLC
ON
SOFT
AP
SHARP*
2nd transport protection screw (Red)
Space for heater unit
q w
e
r
t
y
u
i
o
!0
!1
This Class A digital apparatus complies with cana-
dian ICES-003.
Cet appareil numérique de la classe A est
conforme à la norme NMB-003 du Canada.
For Canada
* Default setting