Appendix 13: Cisco CallManager 
 
 
Cisco CallManager registration
  
 
Configuring an H.323 client on the CallManager 4.0 
 
The registration of a H.323 client in CallManager is supported on the CallManager (CCM) 4.0 
software and forward. 
 
1.  To configure the CallManager with an H.323 client, log on to the administration web 
interface and go to the phone configuration page. 
2.  The Phone configuration page is located on: device (top menu) -> Add a New device -> 
Phone -> H.323 Client. 
3.  In the phone configuration page type the IP address of the TANDBERG system in the 
Device name field, select device pool and push the insert button. 
4.  A pop-up box will now appear on the screen and ask you if you would like to configure 
the directory number. Push the ok button. 
5.  You should now see the Directory Number Configuration WEB page. Enter the 
E.164/phone number of your TANDBERG system in the Directory number field, and in 
the “Forward and Pickup Settings” enter the time of “No Answer Ring Duration”. The time 
selected has to have a value from 1 to 300 seconds. 
6.  Push the Add button to update the CallManager with the directory number settings. 
 
You have now configured the CallManager with a H.323 client and should be able to register the 
TANDBERG system to it. When the TANDBERG system is registered to a CallManager, it will be 
possible to place and receive calls from this system to any other video and voice systems that are 