Panasonic AW-PH400 User Manual

Page of 64
Roll Unit  AW-RL400
AW-RL400
45
Installation
3
Loosen the two screws of camera mounting plate which is already installed to the roll unit.
Then remove the camera mounting plate.
1
Attach the pan/tilt head’s rotary arm to the roll unit using the three mounting screws (M5
!
22 mm, with flat washers, pan/tilt
head accessory).
2
Attach the rotary arm to the pan/tilt head using the mounting screws (M5
!
22 mm, with flat washers, pan/tilt head accessory).
Roll unit
Camera mounting plate
(consisting of 2 separate
sub plates)
Camera mounting plate
(consisting of 2 separate
sub plates)
Rotary arm
Screws
When assembling the units, use the Allen key (provided), wrench and screwdriver, and secure the units by tightening the
screws firmly. After mounting the units, check there is no play in the way they are mounted.