Zebra Technologies radio frequency identification (rfid) User Manual

Page of 162
135
SGD Commands for RFID
rfid.position.program
11/14/2008
RFID Programming Guide
58978L-008 Rev. A
rfid.position.program
Description  This command gets the read/write position of the transponder or sets the 
read/write position in vertical (Y axis) dot rows from the top of the label. Set to 0 (no 
movement) if the transponder is already in the effective area without moving the media.
Type  getvar; setvar
This table identifies the command for this format:
Important • 
If a label format specifies a value for this parameter, this value will be used for 
the programming position for all labels until a new position is specified or until the printer is 
turned off (O) and then back on (I).
Commands
Details
getvar
This command instructs the printer to respond with the current 
programming position. 
Format: ! U1 getvar "rfid.position.program" 
setvar
This command instructs the printer to set the programming position. 
Format: ! U1 setvar "rfid.position.program" "value" 
Values: 
0 to label length
Default value: 
For the R110PAX4 and R2844-Z: 0
For all other supported printers: label length minus 1 mm (1/16 in.)
Default: 1
Example • 
This setvar example shows the programming position being set at 15 dot rows 
from the top of the label. 
! U1 setvar "
rfid.position.program
" "15"
When the setvar value is set to "15", the getvar result is "15".