Installing a Paper-Low Sensor (Optional)
A paper-low sensor alerts the system when a certain length of paper remains on the roll. The
purpose of this sensor is to get an early alert so that you can replace the paper roll in time in
remotely located kiosks.
purpose of this sensor is to get an early alert so that you can replace the paper roll in time in
remotely located kiosks.
All paper roll holders supplied by Zebra can be equipped with paper-low sensors. Mount the
paper-low sensor to the roll holder and connect the cable to the paper-low connector at the
back of the printer.
paper-low sensor to the roll holder and connect the cable to the paper-low connector at the
back of the printer.
Figure 9 • Paper-low Sensor Connection
Figure 10 • Location of Paper-low Connector
+5
+5
Paper-low
sensor
sensor
2
3
1
J10
PL SENSE
SW97081F
200 ohm
100 pF
Paper roll
New
Near
end
end
Roll holder shaft
Gray = Connection
inside printer
Paper low
connector
connector