Fujitsu C150-E049-02EN User Manual

Page of 236
4-16
M3099GX/GH OEM Manual
7 To re-install lamp/heater,
reverse procedures in item
4 above.
Note:
Make sure to rotate lamp in
the direction as shown in the
left figure.
8 Align the lamp unit with
the grooves on the machine
and insert the lamp unit
completely.  Then, turn the
thumb screw completely to
avoid cover open error.
9 Attach the side cover.
Replace the roller ASY as follows:
WARNING
Wait at least 3 minutes after turning off the power before
replacement.
Roller ASY
Replacement
Power switch
Lever
1 Turn off the power switch.
2 Open the upper transport
unit.  (See page 4-2)
Window
Socket
Lamp unit
Thumb screw
Operator panel
Upper transport unit