Kodak 6B7198 User Manual

Page of 112
May 2002
4-1
4  
Maintaining the Equipment
This chapter contains procedures to be done by the person who is responsible for 
maintenance of the HR Film Scanners.
Items required for maintenance are:
Kodak camel’s-hair brush (provided)
dry, untreated microfiber cleaning cloth
lint-free cloth
white cotton gloves
Phillips-head screwdriver
Cleaning Procedures
To minimize the need for cleaning the scanner and to reduce the possibility of 
artifacts, make sure your scanner is in a clean, low-traffic area that does not 
collect much dust. Wood, tile, linoleum, or sealed concrete floors are preferable to 
carpet.
Clean the surface of the scanner with a damp lint-free cloth as needed.
IMPORTANT: Please read the following before performing any cleaning 
procedures.
Avoid using pressurized air or canned air near the scanner. 
If it is necessary to use canned air to clean film, direct the air 
stream away from the scanner.
Instructions for cleaning the balance and IR filters are included under 
Replacement Procedures beginning on page 4-2. 
IMPORTANT: The balance and IR filters are made of glass and are expensive to 
replace. They are not included in the product warranty or service 
contract. Use care when handling the balance and IR filters.
When you remove the filters, inspect them. Cleaning may be all that is required. 
Otherwise, replace the filters as needed.
Cleaning the Lens
IMPORTANT: Wear white cotton gloves for this procedure to prevent oils and dirt 
from being absorbed into the microfiber cleaning cloth.
1. Use the software installed on your host computer to set the magnification to 
2.00, which positions the lens as near to the front of the scanner as possible.
2. Clean the front of the lens with the supplied camel’s-hair brush.
3. Check that the lens is clean; if not, clean with a dry, untreated microfiber 
cleaning cloth.