6
97
6.7.7 o7: Adjustment of the Right and Left Frame Black Band Width
1. Load the Film in the machine and make a print (scan).
<Conditions of printing/scanning>
Size: Letter (A4) Lengthwise
Centering:OFF
Auto Masking:ON
2. Check the width of the black band 
running around the image area.
3. Refer to the charts given below. 
Then, adjust to desired black band 
width by Function Mode o7.
o7
Setting
Adjusted black band width (mm)
d5
-6±3
band width decreases
d6
-4±3
d7
-2±3
d8
0±3
d9
2±3
dA
4±3
db
6±3
band width increases
Image
Feed Direction
A
Right and Left Frame