Commands
Commands are directions issued from an initiator to a target. This image scanner
supports the following range of the commands specified by the SCSI standard.
supports the following range of the commands specified by the SCSI standard.
(a) The identification number of logical unit (LUN: logical unit number) is B©000π.
If this scanner receives a value other than 000, it returns error information as
follows:
follows:
f
Status key: B©00001π (CHECK CONDITION)
f
Sense key: X©5π (ILLEGAL REQUEST)
(b) Relative addressing is not supported.
If this scanner receives a relative address (RelAdr) = 1, it returns error
information as follows:
information as follows:
f
Status key: B©00001π (CHECK CONDITION)
f
Sense key: X©5π (ILLEGAL REQUEST)
(c) A control byte is not supported.
If this scanner receives a control byte b X©00π , it returns error information as
follows:
follows:
f
Status key: B©00001π (CHECK CONDITION)
f
Sense key: X©5π (ILLEGAL REQUEST)