a. TP (third party) :  Byte 1
As this scanner does not support the 3rd party reservation option, setting this
bit to 1 causes the target to return the following error information:
f
Status:   B©00001π (CHECK CONDITION)
f
Sense key:   X©5π (ILLEGAL REQUEST) 
b. TPID (third party device ID) :   Byte 1 
This scanner ignores TPID.
4.4.3
INQUIRY command
The following table shows the normal sequence of the INQUIRY command when
used with this scanner.
Step
Bus phase
Initiator operation
¨ Æ
Target operation
1
BUS FREE
Verifies bus free
2
ARBITRATION
Obtains bus>usage
right
3
SELECTION
Selects target
Æ
Drives BSY signal
4
MESSAGE OUT
Selects logical unit
Æ
5
COMMAND
Specifies INQUIRY
(CDB)
Æ
6
DATA IN
¨
Reports inquiry data
7
STATUS
¨
Reports GOOD status
8
MESSAGE IN
¨
Reports message (Command
Complete)
Releases BSY signal
9
BUS FREE
(1)
INQUIRY command:   COMMAND phase  (initiator Æ target)
The INQUIRY command used to check information regarding a target and logical
unit.  
The CDB of this command is shown in the following illustration.