Panasonic AG-HPX172EN User Manual

Page of 128
1
Appendix
When a P2 card with a memory capacity of 8 
GB or more is used in this unit and a one-time 
continuous recording exceeds the prescribed 
duration (approx. 5 minutes for DVCPRO HD, 
approx. 10 minutes for DVCPRO50 or approx. 
20 minutes for DVCPRO or DV) or when a one-
time recording extends over more than one P2 
card, the recording concerned will automatically 
be undertaken as a separate clip.
At this time, each clip will be provided with its 
own COUNT value.
Example of recording (DVCPRO50) a clip on one P2 card:
REC start 
(recording start)
REC/PAUSE 
(recording pause)
Recording duration = Approx. 15 min.
Clip 1  
COUNT value = 0001
Clip 2  
COUNT value = 0002
10 min.
5 min.
Example of recording a clip on two P2 cards:
REC start 
(recording start)
REC/PAUSE 
(recording pause)
Clip 1  
COUNT value = 0003
Clip 2  
COUNT value = 0004
1st card
2nd card
If the clip thumbnails are displayed as shown in the 
example above or their properties are indicated 
using a P2 device, the thumbnail and COUNT 
value of clip 1 will be displayed.
Selecting the USER CLIP NAME 
recording method
Press the MENU button and select META DATA 
"
 PROPERTY " USER CLIP NAMEto select 
the recording method. Two options are available: 
TYPE1and TYPE2.
TYPE1
USER CLIP NAME to 
be recorded
If clip metadata has 
been read in
Uploaded data
If no clip metadata 
has been read in 
or if the setting 
for recording clip 
metadata has been 
turned off
Same as GLOBAL 
CLIP ID (UMID data)
TYPE2
USER CLIP NAME to 
be recorded
If clip metadata has 
been read in
Uploaded data + 
COUNT value*
If no clip metadata 
has been read in 
or if the setting 
for recording clip 
metadata has been 
turned off
Same as CLIP NAME
*  The COUNT value is indicated as a four-digit 
number.
The COUNT value is incremented each time a 
new clip is captured if clip metadata has been 
read in and TYPE2 has been selected as the 
recording method.
The COUNT value can be reset using the 
following procedure.
Press the MENU button and select META DATA 
"
 PROPERTY " USER CLIP NAME to display 
the menu shown below. Select “COUNT RESET” 
with the cursor and press the Operation lever to 
reset the COUNT value to 1.