Panasonic AJ-P2C002SG User Manual

Page of 206
150
Maintenance and Inspections: Maintenance
6. Inspection of the clock, time code, and user 
bits
1
Set the user bits as required.
Please refer to [Setting of the user bits] (page 62) for the 
setting procedures.
2
Set the time code.
Please refer to [Setting the Time Code] (page 66) for the 
setting procedures.
3
Set the TCG switch to [R-RUN].
4
Press the REC START/STOP button.
Check that the counter display number changes as 
recording progresses.
5
Press the REC START/STOP button again.
Check that recording stops and the counter display 
number stops changing.
6
Set the TCG switch to [F-RUN].
Check that the counter display number changes 
regardless of recording status.
7
Set the DISPLAY switch to [UB].
Each time the HOLD button is pressed, make sure that 
the displayed value changes in the following sequence: 
VTCG  DATE  TIME  No display (time zone)  
TCG; and also verify that the displayed value is correct.
If DATE, TIME, or time zone is not correct, refer to 
[Setting the Internal Clock’s Date and Time] (page 65) 
for guidance on setting the correct values.
Note
Note that date and time data set for DATE, TIME, and 
time zone is recorded in clips, and affects the playback 
sequence, etc. at the time of thumbnail manipulations.
Do not use thinner or other solvents to remove dirt.
Wipe the lens with a commercially available lens cleaner.
Do not wipe the mirror. If dirt or rubbish is sticking on the 
mirror, remove it with a commercially available air blower.
Smears
Smears may appear when shooting an object with very high 
brightness.
This phenomenon becomes more obvious as the electronic 
shutter speed becomes faster.
White defects
When the frame rate is set low during operation under VFR, 
tiny defects may be seen in the video. White defects become 
more noticeable in high-temperature operating conditions.
The camera is shipped from the factory with a backup 
battery already mounted.
When the battery runs out, the “BACKUP BATT EMPTY” 
display appears on the viewfinder screen for 5 seconds after 
the POWER switch is turned [ON].
The internal clock stops operating when the battery runs out. 
Also, the TCG time code value returns to “00:00:00:00”, and 
the time code backup is disabled. The battery must be 
replaced.
Please consult your distributor for replacement with a new 
battery (CR2032).
The backup battery is visible when the panel on the LCD 
monitor side is removed (right side when viewed from the 
front).
Maintenance
Cleaning Inside the Viewfinder
Phenomenon Inherent to CCD Cameras
Replacing the Backup Battery
Note
Please contact the store where you purchased the camera 
when replacing the battery.
AJ-HPX2700G-VQT1V27_eng.book  150 ページ  2008年9月2日 火曜日 午後5時43分