Panasonic AK-HCU200E User Manual

Page of 40
4
Description of information displayed
„
„
WARNING
The warning information is displayed when trouble is detected in the 
unit, camera, or optical fiber multi cable .
The warning information items are displayed top aligned .
A displayed warning information item is cleared when the status 
becomes normal .
         - WARNING -
        CAM RCV LVL NG
        CCU RCV LVL NG
Warning information items
Display item
Description
CAM RCV LVL NG
The level of the optical signal received by the 
camera is low .
CCU RCV LVL NG
The level of the optical signal received by the 
unit is low .
CABLE OPEN
The optical fiber multi cable is not connected .
CABLE SHORT
The optical fiber multi cable is shorted .
CAM FAN NG
Trouble with the cooling fan of the camera .
CCU HIGH TEMP
The temperature of the unit is abnormally high .
CAM WARM-UP
The camera is warming up .
ROP SAVING DATA
The data managed by the camera and this unit 
is being saved to the memory card in the ROP .
To clear the warning information displays, press the button below .
ROP (AK-HRP200): CHARA button
„
„
IRIS display
When the information is not displayed on the picture monitor, display it 
by pressing the CHARA button of the ROP .
The camera number is displayed at the top left of the screen, the IRIS 
level is displayed at the bottom of the screen, and the IRIS f-value is 
displayed at the bottom right of the screen .
Set each item to be displayed on the “PM VIEW SETTING” screen that 
can be accessed by selecting “MAINTENANCE” on the menu .
However, this screen will not appear if the menu’s “IRIS LEVEL” setting 
is “OFF” .
C1
                          F4.8
         C-- --+-----0
Camera number
IRIS f-value
IRIS level*
*:  The IRIS level is displayed based on the IRIS f-value .
„
„
Status displays
From the IRIS display screen, press the CHARA button of the ROP to 
display the statuses .
The camera number, scene file number, shutter value, and extender 
information are displayed at the top of the screen . The ND filter value, 
gain value, and IRIS f-value are displayed at the bottom of the screen .
Set each item to be displayed on the “PM VIEW SETTING” screen that 
can be accessed by selecting “MAINTENANCE” on the menu .
However, when the “IRIS LEVEL” setting is “OFF”, the screen will be 
displayed first if the CHARA button of the ROP is pressed when the 
information is not displayed on the picture monitor .
C1    CAM59.94i  SCENE1  1500
EX DZ×2
EX ×2
 1                12dB   CLOSE
Camera number
Scene file number
Shutter value
ND filter value
Gain value
Extender information
IRIS f-value
Camera format*
*:  The camera format value indicates the format of the signal output 
from the camera .
Picture monitor (PM) displays 
(Continued)