Sony aws-g500 User Manual

Page of 227
139
Controlling Cameras
  C
h
a
p
ter
 3
  O
p
er
at
io
ns
You can also reset the camera by holding down the Shift button and pressing 
the numeric 0 button.
About Camera Tallies
When the camera supports the camera tally function (BRC series, etc.)
The camera tally lamp lights when the input from the camera is being used as 
program output. 
Multiple settings are possible for the [Video Input Assign] [Control] setting.
In this case, the camera tally lights when the video from any of the source viewers 
for which the [Control] setting is made is being used for program output.
When using CCU, etc. 
If the FACTORY USE connector of the unit is connected to the tally connector 
of a CCU (camera control unit), the tally lamp lights for any camera that is 
assigned to a PGM selection button or NEXT selection button on the front panel, 
as long as  video from that camera is being used as program output (the button 
lights red).
Specifications of the FACTORY USE Connector
The specification of each pin is as shown below. 
Note
Caution
Pin 
Number
I/O
Signal 
Name
Description
1
I
-
Unused
2
I
-
Unused
3
I
-
Unused
4
I
-
Unused
5
I
-
Unused
6
I
-
Unused
7
-
GND
GROUND
8
-
GND
GROUND
9
O
GPO0
GIP OUT1: Controls the tally of the camera assigned to 
source number 1. 
On: GND; Off: Open
10
O
GPO1
GIP OUT2: Controls the tally of the camera assigned to 
source number 2. 
On: GND; Off: Open
11
O
GPO2
GIP OUT3: Controls the tally of the camera assigned to 
source number 3. 
On: GND; Off: Open