HDCU-900 MM
3-5-1. VBS Output Level Adjustment
Measures : SD waveform monitor, Vector monitor
Preparation
Board extension : VDA-57 board (rear side)
Adjustment Procedure
1.
SYNC level adjustment
Measuring point : TP202 (B-6)/IF-789A/789P
Adjusting point :
1RV209 (C-6)/IF-789A/789P
Specifications :
A = 571 
±3 mV (for UC)
A = 600 
±3 mV (for CE)
2.
Video level adjustment
Measuring point : TP202 (B-6)/IF-789A/789P
Adjusting point :
1RV202 (D-6)/IF-789A/789P
Specifications :
B = 1429 
±5 mV (for UC)
B = 1400 
±5 mV (for CE)
3.
VBS1 OUT level adjustment
Measuring point : VBS OUT1 connector/VDA-57
Adjusting point :
1RV62 (L-5)/VDA-57
Specifications :
C = 100.0 
±0.5 IRE
(terminated at 75 
Z) (for UC)
C = 700.0 
±3.5 mV
(terminated at 75 
Z) (for CE)
4.
VBS2 OUT level adjustment
Measuring point : VBS OUT2 connector/VDA-57
Adjusting point :
1RV61 (M-4)/VDA-57
Specifications :
D = 100.0 
±0.5 IRE
(terminated at 75 
Z) (for UC)
D = 700.0 
±3.5 mV
(terminated at 75 
Z) (for CE)
5.
Chroma adjustment
Adjust the PHASE knob of the vector monitor so that
75% of the luminescent spot of the burst is aligned
with the axis.
Measuring point : VBS OUT1 connector/VDA-57
Adjusting point :
1RV208 (C-7)/IF-789A/789P
Specifications :
The luminescent spot should be
located inside “
4”.
3-5-2. PIX Output Level Adjustment
Measure : SD waveform monitor
Preparation
. The VBS output level adjustment (section 3-5-2) should
be completed.
. PIX monitor select switch/MSU → ENC
. Board extension : VDA-57 board (rear side)
Adjustment Procedure
1.
PIX signal level adjustment
Measuring point : PIX OUT connector/VDA-57
Adjusting point :
1RV121 (F-5)/VDA-57
Specifications :
A = 100.0 
±0.5 IRE
(terminated at 75 
Z) (for UC)
A = 700 
±3.5 mV
(terminated at 75 
Z) (for CE)
2.
PIX monitor select switch/MSU 
→ R, G or B
3.
SYNC level adjustment
Measuring point: PIX OUT connector/VDA-57
Adjusting point:
1RV207 (C-6)/IF-789A/789P
Specifications:
B = 40.0  
±0.5 IRE
(terminated at 75 
Z) (for UC)
B = 300.0 
±3.5 mV
(terminated at 75 
Z) (for CE)
4.
Video level adjustment
Measuring point : PIX OUT connector/VDA-57
Adjusting point :
1RV204 (D-6)/IF-789A/789P
Specifications :
C = 75.0 
±0.5 IRE
(terminated at 75 
Z) (for UC)
C = 525.0 
±3.5 mV
(terminated at 75 
Z) (for CE)
Setting after Adjustment
PIX monitor select switch/MSU 
→ ENC
[for CE]
[for UC]
B,
C, 
D
B,
C, 
D
A
A
R
M
G
B
C
Y
G
Y
L
R
M
G
C
Y
G
Y
L
B
[for UC]
[for CE]
[for CE]
[for UC]
A
A
3-5. SD Signal System Adjustment (HKCU-901)
C
B