Chauvet LED PAR 64-36C User Manual

Page of 18
 
4. Operating Instructions 
12 
10/27/2009 1:10 PM 
4.
 
O
PERATING 
I
NSTRUCTIONS
 
 
DMX Operation 
 
 
This is the operating mode which will allow for control with an external DMX controller. You must set 
the starting address for this mode. If this is your first time using DMX, then it is recommended that 
you refer to the “DMX Primer” section in the “Appendix” of this manual. 
 
 
Mode 
 
DIP switches 
DMX  
 
1~9 = set to the DMX starting address 
 
 
 
10 = Off 
 
Accessing the 2 Personalities: 
There are two personalities for this fixture. There is the standard 7-channel personality with strobe 
and color macros, and then there is the basic 3-channel RGB personality. Please see the DIP switch 
settings to access each of these personalities below. 
 
Mode 
 
DIP switches 
7-CH 
 
11-12 = Off 
3-CH 
 
11 = On 
 
Master/Slave Mode (Sound-Active, Auto Mode, Static Colors): 
This mode allows a single unit to run a standalone program, while 1 or more other units follow the 
same operation. This requires the fixtures to be linked with DMX cables. Please see the section on 
Fixture Linking
1) 
Turn switch to the Slave position on the slave units, and they will react the same as the Master. 
 
Mode 
 
DIP switches 
Slave 
 
1~11 = Off 
 
Strobe Speed: 
This fixture has a strobe speed adjustment which will make it compatible with CHAUVET LED PAR 
64-36 models produced before July of 2009. Please see the setting below for lowering the strobe rate 
for compatibility mode. 
 
Mode 
 
DIP switches 
 
Compatibility mode 
6 Hz~18 Hz: 
 
12 = On 
 
Decreased Speed 
2 Hz~6 Hz: 
 
12 = Off