6.4.1 Connecting the Keyboard 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
PELCO Keyboard (or compatible) Installation 
The  RS-422  interface  is  used  for  communicating  with  a  PELCO  keyboard.  Refer  to  Fig.  1; 
connect  R+  of  the  camera  to  T+  of  the  PELCO  keyboard.  Connect  R-  of  the 
camera to T- of the PELCO keyboard. 
The  user  can  adjust  Camera  ID  via  rear  panel  keys  or  via  remote  commands. 
Protocol, Speed and Parity should only be adjusted via rear panel keys. 
 
Communication 
Setting 
0 ~ 253 for P protocol 
CAMERA ID 
1 ~ 255 for D protocol 
PROTOCOL 
PELCO 
SPEED 
2400, 4800, 9600, 19200 
PARITY 
NONE 
The  speed  of  camera  should  be  the  same  as  the  speed  of  the  keyboard. 
Adjusted function is only effective, after exiting the OSD setup menu. 
 
Note
Maximum cable distance for RS-485 coMmunication over 24-gauge wire is 4,000 
feet (1,219 m). Recommend using a shielded twisted pair cable that meets the basic 
requirements for EIA RS-485 applications.