Panasonic AJ-HPX3100G User Manual

Page of 208
153
Maintenance and Inspections: Warning System
 Mai
n
ten
ance an
d Insp
ecti
o
n
s
If a problem is detected immediately after the power is turned on, or during operation, this will be indicated by the WARNING 
lamp, lamps inside the viewfinder and a warning tone. 
‹
Note
The WARNING lamp has the highest priority, followed by the tally lamp, and then the warning tone. When multiple errors occur 
simultaneously a higher priority indication will be triggered. The [9. Low Wireless Signal Reception], however, may not be 
indicated, depending on the menu setting. 
Warning System
Warning Description Tables
1. System Errors
Display window 
indication 
The error code lights up.
WARNING lamp 
Blinks 4 times per second. 
Tally lamp
Blinks 4 times per second. 
Viewfinder
The SYSTEM ERROR indication and the error 
code light up. 
Warning tone
Beeps continuously. 
Warning 
description 
An error in the reference signal or the 
communication. 
Recording/
playback 
operation 
The operation stops. 
Countermeasures
Please confirm  [Error Codes] (page 155) and 
consult your distributor.
3. Battery Empty
Display window 
indication 
All 7 bar indicators for battery remaining 
capacity start blinking. 
WARNING lamp 
Lights up. 
Tally lamp
Blinks once per second. 
Viewfinder
The BATT LED lights up. 
Warning tone
Beeps continuously. 
Warning 
description 
The battery has run out. 
Recording/
playback 
operation 
The operation stops. 
Countermeasures
Replace the battery. 
2. Card removal error
Display window 
indication 
Error code E-30 blinks.
WARNING lamp 
Blinks 4 times per second.
Tally lamp
Blinks 4 times per second.
Viewfinder
The “TURN POWER OFF” indicator lights up.
Warning tone
Continues to beep.
Warning 
description 
The P2 card being accessed has been 
removed, resulting in an error in the internal 
memory of the camera-recorder.
Recording/
playback 
operation 
Cannot be performed.
Countermeasures
Turn off the power to the camera-recorder. If 
there is an error in a clip on the removed P2 
card, repair the clip.
4. P2 Card Fully Recorded
Display window 
indication 
All 7 bar indicators for remaining MEDIA 
capacity start blinking. 
WARNING lamp 
This lamp will illuminate continuously until an 
operation is made after recording.
Tally lamp
This lamp will flash 4 times every second until 
an operation is made after recording.
Viewfinder
The END indicator blinks. 
Warning tone
This tone will sound continuously until an 
operation is made after recording.
Warning 
description 
The P2 cards are recorded to maximum 
capacity. 
Recording/
playback 
operation 
The recording stops. 
Countermeasures
Delete the clips in the P2 card or insert a new 
P2 card. 
AJ-HPX3100G(VQT3A79)_E.book  153 ページ  2010年9月17日 金曜日 午後9時21分