Panasonic AJ-HPX3100G User Manual

Page of 208
39
Recording and Playback: Loop Recording
 Recor
d
in
g an
d Pl
ayb
ack
When two P2 card slots contain cards, this function allows 
the target P2 card to be switched in order. Even when the 
free space of a P2 card is used up, this function continues 
recording while erasing existing data. 
To use this function, the menu option LOOP REC MODE 
must be set to “ON”. The menu item FLOOP REC MODE is 
found in the  <REC FUNCTION> screen on the SYSTEM 
SETTING page.
‹
Notes
z
When the LOOP REC capability is used, each P2 card must 
have at least one minute of free space.
z
During LOOP REC, the P2 CARD ACCESS LEDs for all target 
P2 cards illuminate in orange. Note that if any of the target P2 
card is removed, LOOP REC stops.
z
When the menu option LOOP REC MODE is set to ON, the 
viewfinder and display window both show “LOOP”.
However, when only one card is inserted, or when each card 
has less than one minute of free space, the LOOP REC 
capability does not work, even if the option LOOP REC 
MODE is set to ON. If this is the case, the indication “LOOP” 
flashes in the viewfinder and on the display window.
z
When the menu option LOOP REC MODE is set to “ON”, the 
space remaining on the P2 card is displayed as an estimated 
recording time for the current recording format. When LOOP 
REC is stopped immediately after deleting an old recording, 
the actual time remaining may be shorter than the displayed 
time.
z
LOOP REC function does not work when: 
Š
the INTERVAL REC MODE menu option is set to “ON” or 
“ONE SHOT”. 
Š
the ONE CLIP REC MODE menu option is set to “ON”. 
Š
Native mode, 24P or 24PA mode is selected in the REC 
FORMAT or CAMERA MODE menu option. 
Š
the REC SIGNAL menu option is set to “SDI”. 
> [Recording Setting and Operation Mode] (page 46)
You can terminate the LOOP REC mode by either:
z
Turning off the POWER switch of camera-recorder; or
z
Setting the menu option LOOP REC MODE to “OFF”. 
It is possible to record in intervals of one frame as the 
shortest length by using the internal memory of the unit.
To use this option,  set the interval recording mode, REC 
TIME, PAUSE TIME and TAKE TOTAL TIME for the menu 
option INTERVAL REC MODE. When the settings are 
finalized, TOTAL REC TIME needed on the P2 card is 
automatically calculated and displayed. The menu item 
INTERVAL REC MODE is found in the  <REC FUNCTION> 
screen on the SYSTEM SETTING page.
The following are the options for INTERVAL REC MODE:
OFF: 
No interval recording performed.
ON:
  Interval recording performed.
ONE SHOT:
Performs “one-shot” recording for the duration 
specified under the REC TIME option by pressing the 
REC button.
Loop Recording
B
A
B
C
Card1
Card2
Recording starts
Before LOOP
REC starts
Recording
Cycle 1
Data is recorded by connecting the unrecorded sections on the 
P2 card (in the sequence of A to B). When the remaining 
recording space becomes zero, A is erased and new data is 
recorded (C).
Recording
Cycle 2
No content
Content 
recorded
Terminating the LOOP REC Mode
Interval Recording
AJ-HPX3100G(VQT3A79)_E.book  39 ページ  2010年9月17日 金曜日 午後9時21分