Panasonic AJ-HDX900 User Manual

Page of 134
128
TYPE A
2
/
11.0
13.6
15.0
12.0
14.6
17.0
For enabling or disabling the selection made
for the BATTERY SELECT item.
2
The selection is enabled.
/ : The selection is disabled.
For selecting in 0.1 V steps the voltage at
which the battery charge is to be considered
nearly depleted.
For selecting in 0.1 V steps the voltage at
which FULL is to be displayed.
11.0
12.9
15.0
For selecting in 0.1 V steps the voltage at
which the battery charge is to be considered
depleted.
TYPE B
2
/
11.0
13.0
15.0
12.0
15.2
17.0
For enabling or disabling the selection made
for the BATTERY SELECT item.
2
The selection is enabled.
/ : The selection is disabled.
For selecting in 0.1 V steps the voltage at
which the battery charge is to be considered
nearly depleted.
For selecting in 0.1 V steps the voltage at
which FULL is to be displayed.
11.0
12.4
15.0
For selecting in 0.1 V steps the voltage at
which the battery charge is to be considered
depleted.
FULL
NEAR END
END
FULL
NEAR END
END
Item
Variable
range
Remarks
NICD14
NEAR END
END
2
/
11.0
13.8
15.0
For enabling or disabling the selection made
for the BATTERY SELECT item.
2
The selection is enabled.
/ : The selection is disabled.
For selecting in 0.1 V steps the voltage at
which the battery charge is to considered
nearly depleted.
11.0
13.2
15.0
For selecting in 0.1 V steps the voltage at
which the battery charge is to be considered
depleted.
7-8-4 BATTERY SETTING2
C U F
C U F
C U F
Chapter 7  Menu description tables 
(continued)
Item
Variable
range
Remarks
ENDURA10
2
/
AUTO
MANUAL
For enabling or disabling the selection made
for the BATTERY SELECT item.
2
The selection is enabled.
/ : The selection is disabled.
For selecting how the voltage at which the
battery charge is considered nearly depleted
is to be set.
AUTO:
The voltage is set automatically.
MANUAL: The voltage is set manually.
11.0
13.2
15.0
For selecting the voltage at which the battery
charge is to be considered nearly depleted in
0.1 V steps when MANUAL has been selected
as the setting for the menu item above.
C U F
ENDURA-D
2
/
AUTO
MANUAL
For enabling or disabling the selection made
for the BATTERY SELECT item.
2
The selection is enabled.
/ : The selection is disabled.
For selecting how the voltage at which the
battery charge is considered nearly depleted
is to be set.
AUTO:
The voltage is set automatically.
MANUAL: The voltage is set manually.
11.0
13.2
15.0
For selecting the voltage at which the battery
charge is to be considered nearly depleted in
0.1 V steps when MANUAL has been selected
as the setting for the menu item above.
C U F
PAG L95
2
/
AUTO
MANUAL
For enabling or disabling the selection made
for the BATTERY SELECT item.
2
The selection is enabled.
/ : The selection is disabled.
For selecting how the voltage at which the
battery charge is considered nearly depleted
is to be set.
AUTO:
The voltage is set automatically.
MANUAL: The voltage is set manually.
11.0
13.5
15.0
For selecting the voltage at which the battery
charge is to be considered nearly depleted in
0.1 V steps when MANUAL has been selected
as the setting for the menu item above.
C U F
BP-GL65/95
2
/
AUTO
MANUAL
For enabling or disabling the selection made
for the BATTERY SELECT item.
2
The selection is enabled.
/ : The selection is disabled.
For selecting how the voltage at which the
battery charge is considered nearly depleted
is to be set.
AUTO:
The voltage is set automatically.
MANUAL: The voltage is set manually.
11.0
13.6
15.0
For selecting the voltage at which the battery
charge is to be considered nearly depleted in
0.1 V steps when MANUAL has been selected
as the setting for the menu item above.
C U F
The underlining in the variable range column indicates the setting in the preset
mode.
O
When the digital battery is attached in the unit, the
remaining capacity of the battery is displayed in percent.
01.AJ-HDX900_P_E(VQT0X86)_E  06.6.22  12:53 PM  ページ128