 NOTE
• When a P2 card is being accessed or recognised after 
insertion (P2 CARD ACCESS LED blinks in orange), do not 
remove the P2 card. Removing a P2 card during access could 
damage it.
• If a P2 card being accessed is removed, the viewfinder 
displays “TURN POWER OFF” and the AG-HPX370P/AG-
HPX371E gives a warning using an alarm and the WARNING 
LED. In addition, all P2 CARD ACCESS LEDs blink rapidly in 
orange. If this is the case, turn the power off.  
For details, refer to [Warning System] (page 161).
• Removing a P2 card during access may corrupt clip data. 
Check the clips and restore them if required.  
For details, refer to [Restoring Clips] (page 118).
• If a P2 card being formatted is removed, it may be not be 
formatted properly. In this case, the viewfinder displays 
“TURN POWER OFF”. If this message appears, turn off the 
power, then restart the AG-HPX370P/AG-HPX371E to reformat 
the card.
• If a P2 card is inserted while another P2 card is being played 
back, the inserted P2 card is not recognised and the P2 
CARD ACCESS LED for that card does not come on. Card 
recognition starts when playback ends.
• A P2 card inserted in an empty slot during recording may not 
be immediately recognized during the following events.
  • Immediately following PRE REC operation
• The CARD ACCESS LED can be set to stay off in the menu 
option ACCESS LED in the OTHER FUNCTIONS screen. 
When the camera is used in this way, remove cards when the 
camera has been powered down or a sufficiently long time 
after terminating recording, playback and other operating 
modes.
• Removing a P2 card during thumbnail display terminates the 
thumbnail display.
To Prevent Accidental Erasure of 
P2 Card Content
To prevent the content of a P2 card being accidentally 
erased, position the write-protect switch on the P2 card at 
[Protect].
Write-protectswitch
 NOTE
Write-protect switchover can be performed while the card is 
being accessed (during recording or playback), but does not 
take effect until access to the card ceases.
P2 CARD ACCESS LED and status 
of P2 cards
P2 
CARD 
ACCESS 
LED
Status of P2 Card
MODE 
CHECK 
indication
 *1
Stays on 
in green
Recording 
enabled
Writing and 
reading enabled.
ACTIVE
Stays on 
in orange
Selected for 
recording
Writing and 
reading enabled 
for current 
recording mode 
(loop, interval 
or one-shot 
recording).
ACTIVE
Blinks in 
orange
 *2
Being 
accessed
Writing or reading 
being performed. ACCESSING
Quickly 
blinks in 
orange
Being 
recognized
The P2 card is 
being recognised.
INFO 
READING
Blinks in 
green
Card full
The P2 card has 
no free space. 
Only reading is 
enabled.
FULL
Write-
protected
The write-protect 
switch on the P2 
card is positioned 
at [PROTECT]. 
Only reading is 
enabled.
PROTECTED
Stays off
Card not 
supported
The card is not 
supported by your 
AG-HPX370P/
AG-HPX371E. 
Replace the card.
NOT 
SUPPORTED
Incorrect 
format
The P2 card 
is not properly 
formatted. 
Reformat the card.
FORMAT 
ERROR
Card not 
inserted
No P2 card is 
inserted.
Card recognition 
standby.
NO CARD
*1   MODE CHECK appears in the viewfinder and on the 
LCD monitor.
For details, see [Viewfinder Screen Status Displays] 
(page 74).
*2   Blinks orange also when a PROXY card (optional 
accessory) is inserted in slot 2.