Chapter 5 Preparation — Connecting the <DC OUT> terminal with the external recording start/stop switch
Connecting the <DC OUT> terminal with the external recording start/stop switch
It is possible to retrieve 1.5 A current from the <DC OUT> terminal of the camera.
Recording start/stop can be controlled by connecting an external switch to this terminal.
Since a tally lamp can be used by connecting an LED to this terminal, it is useful for shooting video when fixing the camera on a crane.
<DC OUT> terminal
(Connection example)
1
2
3
4
LED
Resistance
start/stop
Cable connector
HR10A-7R-4SC (73)
Hirose Electric Co.
Recording
1  GND
2  TALLY OUT
Open collector output on the camera side
Tally lamp on
Low impedance
Tally lamp off
High impedance
3  Recording start/stop switch
This is connected in parallel to the <REC> button on the camera or 
the VTR button on the lens.
4  +12 V
@
@
NOTE
 tMake sure that polarity is correct before connecting an external 
device. Failure to do so may result in a malfunction.