Sony DVW-790WS/790WSP User Manual

Page of 314
5-18
DVW-790WS/709WS/707
DVW-790WSP/709WSP/707P P2V1
5-4. CTL Head Position Adjustment
Notes
. The CTL head position adjustment is closely related to the CUE/TC head position adjustment.
. After carrying out the CTL head position adjustment, be sure to carry out the CUE/TC head position
check.
Tools
. TP tool
: J-6420-910-A
. Alignment tape, ZR2-1 (NTSC)
: 8-960-073-11
. Alignment tape, ZR2-1P (PAL)
: 8-960-073-61
. Torque screwdriver bit (for M2)
: J-6325-380-A
. Torque screwdriver (for 3 kg)
: J-6325-400-A
. Oscilloscope
Setting
1.
Turn the power off.
2.
Connect the 8-pin connector of the TP tool to the connector CN7 on the HN-260 board.
3.
Connect the 5-pin connector of the TP tool to the connector CN3 on the CTL-10 board.
4.
Set the switches S1-1 and S1-2 on the HN-260 board to OFF.
5.
Connect an oscilloscope.
CH-1
:
REC RF A/TP tool
CH-2
:
PB CTL/TP tool
TRG
:
SV REF CF/TP tool
6.
Turn the power on.
7.
Insert the alignment tape ZR2-1/P.
5-4. CTL Head Position Adjustment