Sony DVW-790WS/790WSP User Manual

Page of 314
5-23
DVW-790WS/709WS/707
DVW-790WSP/709WSP/707P P2V1
5-6. CUE Head Azimuth Check
Notes
. The check whether the CUE head azimuth is correctly adjusted or not is extremely difficult from the
point of the tape running system.
Do not perform this check, but adjust the CUE head azimuth according to the following procedures.
. The CUE head azimuth check the position and height adjustments of the CUE head.
. After carrying out the CUE head azimuth adjustment, be sure to carry out the adjustments or checks of
the CUE head.
Tools
. Alignment tape, ZR2-1 (NTSC)
: 8-960-073-11
. Alignment tape, ZR2-1P (PAL)
: 8-960-073-61
. TP tool
: J-6420-910-A
. Oscilloscope
Setting
1.
Turn the power off.
2.
Connect the 8-pin connector of the TP tool to the connector CN7 on the HN-260 board.
3.
Connect the 5-pin connector of the TP tool to the connector CN3 on the CTL-10 board.
4.
Set the switches S1-1 and S1-2 on the HN-260 board to OFF.
5.
Connect an oscilloscope.
CH-1: PB CUE/TP tool
6.
Turn the power on.
7.
Insert the alignment tape ZR2-1/P.
5-6. CUE Head Azimuth Check