Sony DVW-790WS/790WSP User Manual

Page of 314
6-2
DVW-790WS/709WS/707
DVW-790WSP/709WSP/707P P2V1
6-2. Power System Adjustment
6-2-1. Battery End Detection Voltage
Adjustment
Preparation
. Connect as follows.
. Supply +12 V DC to the DC IN connector.
Adjustment Procedure
1.
Insert a work tape
*1 
(BCT-D40) and enter the recording
mode.
*
1 : A work tape that is not used so many times is desired.
The already recorded tape can be used. However, note that the
previous signals will be erased during adjustment.
2.
Measurement point : DC IN connector
Adjust the output voltage of the external regulated DC
power supply until the following specification is satis-
fied:
Spec.
: 11.28 
±
 0.02 V DC
3.
Press the DIAG button (inside panel) to enter the DIAG
menu.
4.
Keep pressing the HOLD button (inside panel) and con-
firm that the WARNING indicator turns on momentari-
ly.
If not, repeat the adjustment from step 1.
6-2. Power System Adjustment
OVER   EMPH   OVER
DIAG  PB VITC NDF EXT-LK                HOLD
V
H
TAPE
BATT
2
1
PEAK dB
E
B
E
F
RF       SERVO       HUMID       SLACK
H         MIN       SEC        FRM
0
20
10
30
.
40
BATT level
meter
Display window
DIGITAL
VOLTMETER
REGULATED
DC POWER SUPPLY
DC IN
DVW-790WS/709WS/707
DVW-790WSP/709WSP/707P
Check Procedure
1.
Enter the STOP mode.
2.
Turn the POWER switch off and back on.
3.
Enter the REC mode.
4.
Measurement point : DC IN connector
Adjust the output voltage of the external regulated DC
power supply until the following specification is satis-
fied:
Spec.
: 11.28 
±
 0.02 V DC
5.
Check the display window.
BATT level meter : The three indicators on the left
turn on.
6.
Increase the output voltage of the external regulated DC
power supply gradually until seven indicators (FULL)
of the BATT level meter turn on.  Measure the output
voltage of the external regulated DC power and confirm
that the following specification is now satisfied:
Spec.
: 11.98 
±
 0.02V