Sony DVW-790WS/790WSP User Manual
7-12
DVW-790WS/709WS/707
DVW-790WSP/709WSP/707P P2V1
7-7. TEST SAW Adjustment
Preparation
. OUTPUT/DCC switch (inside panel)
→
CAM/ON
. WHITE BAL switch (inside panel)
→
PRST
Adjustment Procedure
Equipment
: Waveform monitor
Test point
: TEST OUT connector
1.
On the setup menu, set as follows.
PAGE
PAGE
: S12
*FUNCTION 1/2
ITEM
: GAMMA
→
OFF
2.
AUTO W/B BAL switch (front panel)
→
BLK
(Perform the automatic black balance adjustment.)
3.
On the setup menu, adjust as follows.
PAGE
: S21
*LEVEL 4
ITEM
: MASTER BLACK
Spec.
: A = 8.0
± 0.2 IRE (NTSC)
A = 2.0
±1.0 mV (PAL)
4.
On the setup menu, set as follows.
PAGE
PAGE
: S53
*VA ADJ. 2/2
ITEM
: TEST SAW
→
ON
5.
On the setup menu, set as follows.
PAGE
PAGE
: S53
*VA ADJ. 2/2
ITEM
: TEST OUT
→
G
6.
On the setup menu, adjust as follows.
PAGE
PAGE
: S52
*VA ADJ. 1/2
ITEM
: TEST LEVEL
Spec.
: B = 100
± 2 IRE (NTSC)
B = 700
±10 mV (PAL)
Setting After Adjustment
. On the setup menu, set as follows.
PAGE
: S12
*FUNCTION 1/2
ITEM
: GAMMA
→
ON
ITEM
: TEST SAW
→
OFF
ITEM
: TEST OUT
→
ENC
A
B
7-7. TEST SAW Adjustment