Sony DVW-790WS/790WSP User Manual

Page of 314
7-29
DVW-790WS/709WS/707
DVW-790WSP/709WSP/707P P2V1
7-17-5. Detail Level Adjustment (4:3)
4:3 mode
Note
Perform this adjustment, if necessary, to suit the custom-
er’s preferences.
Preparation
. On the setup menu, set as follows.
PAGE
: S12
*FUNCTION 1/2
ITEM
: DETAIL
 ON
ITEM
: TEST OUT
 ENC
. Shoot a grayscale chart (4:3) in the full underscanned
monitor frame.
Equipment
: Waveform monitor
Test point
: TEST OUT connector
Setting point
:
1 Lens IRIS
Spec.
: A = 80 
±2 IRE (NTSC)
A = 560 
±14 mV (PAL)
 Adjustment Procedure
Equipment
: Waveform monitor
Test point
: TEST OUT connector
1.
Select the 4:3 mode.
PAGE
: S14
*WIDE SCREEN
ITEM
: 16:9/4:3 MODE 
 4:3
2.
On the setup menu, adjust as follows.
PAGE
: S18
*LEVEL 1#4:3
ITEM
: DETAIL LVL <4:3>
(Factory setting: 0)
Spec.
: Adjust the detail amount which is
added to each step in the grayscale
chart for the customer’s preferences.
7-17-6. Knee Aperture Adjustment (4:3)
4:3 mode
Note
Perform this adjustment, if necessary, to suit the custom-
er’s preferences.
Preparation
. On the setup menu, set as follows.
PAGE
: S12
*FUNCTION 1/2
ITEM
: DETAIL
 ON
ITEM
: TEST OUT
 ENC
PAGE
: S19
*LEVEL 2#4:3
ITEM
: KNEE APT. <4:3>
 ON
. OUTPUT/DCC switch (inside panel) 
 CAM/ON
. Shoot a grayscale chart (4:3) in the full underscanned
monitor frame.
Equipment
: Waveform monitor
Test point
: TEST OUT connector
Setting point
:
1 Lens IRIS
Spec.
: A = 100 
± 2 IRE (NTSC)
A = 700 
±14 mV (PAL)
. GAIN switch (inside panel) 
 M (9 dB)
 Adjustment Procedure
Equipment
: Waveform monitor
Test point
: TEST OUT connector
1.
Select the 4:3 mode.
PAGE
: S14
*WIDE SCREEN
ITEM
: 16:9/4:3 MODE 
 4:3
2.
On the setup menu, adjust as follows.
PAGE
: S19
*LEVEL 2#4:3
ITEM
: K.APT. LVL <4:3>
Spec.
: Adjust the peak-to-peak level of the
noise at the third steps from the top
(portion B) in the gray-scale chart, as
desired. (Reference level is 40 mV)5
A
A
7-17. Detail Signal Adjustment (4:3)
B