Sony DVW-790WS/790WSP User Manual

Page of 314
8-11
DVW-790WS/709WS/707
DVW-790WSP/709WSP/707P P2V1
4.
On the setup menu, set as follows.
PAGE
: S12
*FUNCTION 1/2
ITEM
: TEST OUT 
 ENC
ITEM
: GAMMA 
 OFF
5.
Select portion C by using the waveform monitor.
6.
Set the waveform monitor to the CHROMA mode.
7.
Equipment
: Waveform monitor
Test point
: TEST OUT connector
Adj. point
:
1RV101 (VA-191 board (R GIAN))
1RV301 (VA-191 board (B GAIN))
Spec.
: Minimize carrier leakage D by using
the variable resistors alternately.
Setting After Adjustment
. On the setup menu, set as follows.
PAGE
: S12
*FUNCTION 1/2
ITEM
: GAMMA 
 ON
8-9. VA Gain Adjustment
Note
Use an 89.9%-reflective chart in this adjustment as possi-
ble. (Refer to Section 8-1-4.)
Preparation
. OUTPUT/DCC switch (inside panel) 
 CAM/ON
. Shoot a grayscale chart in the full underscanned monitor
frame.
. WHITE BAL switch (inside panel) 
 PRST
. AUTO W/B BAL switch (front panel) 
 BLK
(Perform the automatic black balance adjustment.)
. On the setup menu, set as follows.
PAGE
: S35
*PRESET WHT
ITEM
: COLOR TEMP <P> : 3200
ITEM
: R GAIN <P>
: 0
ITEM
: B GAIN <P>
: 0
Adjustment Procedure
1.
Equipment
: Oscilloscope
Test point
: TP1 (VA-191 board)
Setting point :
1Lens IRIS
Spec.
: A = 320 
±
8 mV
2.
On the setup menu, set as follows.
PAGE
: S12
*FUNCTION 1/2
ITEM
: TEST OUT 
 G
3.
Equipment
: Waveform monitor
Test point
: TEST OUT connector
Adj. point
:
1RV201 (VA-191 board (G GAIN))
Spec.
: B = 100 
±
2 IRE (NTSC)
B = 700 
±
10 mV (PAL)
A
B
C
D
8-9. VA Gain Adjustment
VA-191 board (A side)
1
RV101
1
RV201
TP1
1
RV301
A
1
2
3
C
B
D
E