8-21
DVW-790WS/709WS/707
DVW-790WSP/709WSP/707P P2V1
8-16-5. Detail Level Adjustment
Note
Perform this adjustment, if necessary, to suit the custom-
er’s preferences.
Preparation
. On the setup menu, set as follows.
PAGE
: S12
*FUNCTION 1/2
ITEM
: DETAIL 
 ON
ITEM
: TEST OUT 
 ENC
. Shoot a grayscale chart in the full underscanned monitor
frame.
Equipment
: Waveform monitor
Test point
: TEST OUT connector
Setting point
:
1Lens IRIS
Spec.
: A = 80 
±
2 IRE (NTSC)
A = 560 
±
14 mV (PAL)
Adjustment Procedure
Equipment
: Waveform monitor
Test point
: TEST OUT connector
1.
On the setup menu, adjust as follows.
PAGE
: S16
*LEVEL 1
ITEM
: DETAIL LVL (Factory setting : 0)
Spec.
: Adjust to the detail amount which is added
to each step in the grayscale chart for the
customer’s preferences.
8-16-6. Knee Aperture Adjustment
Note
Perform this adjustment, if necessary, to suit the custom-
er’s preferences.
Preparation
. On the setup menu, set as follows.
PAGE
: S12
*FUNCTION 1/2
ITEM
: DETAIL
 ON
ITEM
: TEST OUT
 ENC
PAGE
: S17
*LEVEL 2
ITEM
: KNEE APT.
 ON
. OUTPUT/DCC switch (inside panel)
 CAM/ON
. Shoot a grayscale chart in the full underscanned monitor
frame.
Equipment
: Waveform monitor
Setting point
:
1 Lens IRIS
Spec.
: A = 100 
±
2 IRE (NTSC)
A = 700 
±
14 mV (PAL)
. GAIN switch (inside panel) 
 M (9 dB)
 Adjustment Procedure
Equipment
: Waveform monitor
Test point
: TEST OUT connector
1.
On the setup menu, adjust as follows.
PAGE
: S17
*LEVEL 2
ITEM
: K.APT.LVL
Spec.
: Adjust the peak-to-peak level of the
noise at the third steps from the top
(portion B) in the grayscale chart, as
desired. (Reference level is 40 mV)
8-16. Detail Signal Adjustment
A
A
B