Sony DVW-790WS/790WSP User Manual
8-25
DVW-790WS/709WS/707
DVW-790WSP/709WSP/707P P2V1
8-19. Automatic Iris Adjustment
Preparation
. On the setup menu, set as follows.
PAGE
: S24
*LEVEL 7
ITEM
: TEST OUT
→
ENC
. OUTPUT/DCC switch (inside panel)
→
CAM/ON
. Shoot a grayscale chart in the full underscanned monitor
frame.
. Lens IRIS
→
AUTO
Adjustment Procefure
Equipment
: Waveform monitor
Test point
: TEST OUT connector
1.
On the setup menu, adjust as follows.
PAGE
PAGE
: S29
*LEVEL 12
ITEM
: IRIS MODE
Spec.
: Set depending on the application.
(Automatic iris operation mode setting can
be done from the average level to peak-to-
peak level of the video signal.)
be done from the average level to peak-to-
peak level of the video signal.)
IRIS MODE = MIN
→
peak-to-peak level
IRIS MODE = MAX
→
average level
2.
On the setup menu, adjust as follows.
PAGE
PAGE
: S29
*LEVEL 12
ITEM
: IRIS SET
Spec.
: A = 100
±
2 IRE (NTSC)
A = 700
±
14 mV (PAL)
3.
On the setup menu, set as follows.
PAGE
PAGE
: S29
*LEVEL 12
ITEM
: IRIS WEIGHT
→
0 (MIN)
4.
Shoot an area where the auto iris is not wanted to work
in the white window chart.
in the white window chart.
5.
On the setup menu, adjust as follows.
PAGE
PAGE
: S29
*LEVEL 12
ITEM
: IRIS WEIGHT
Spec.
: Increment the IRIS WEIGHT value until
the lens iris is open.
6.
On the setup menu, adjust as follows.
PAGE
PAGE
: S29
*LEVEL 12
ITEM
: IRIS SPEED (Factory setting : 2)
Spec.
: Adjust for the desired operation speed of
auto iris.
7.
On the setup menu, set as follows.
PAGE
PAGE
: S29
*LEVEL 12
ITEM
: CLIP HIGH LIGHT
→
ON or OFF
Spec.
: Set to the desired position.
8-19. Automatic Iris Adjustment