Sony DXC-D35 User Manual
3-14
DXC-D35/D35WS(UC)
DXC-D35P/D35WSP(CE) V1
3.
Adjust the lens iris to bring the white level “A” to 70
±
2 IRE.
Test point:
VIDEO OUT connector
4.
In the following items, by pressing the UP or
DOWN switches, adjust the waveform of the
oscilloscope to be flat.
DOWN switches, adjust the waveform of the
oscilloscope to be flat.
GND: TP38/EX-490 board
Item
Test point
Specification
R W. SHAD
CL101
G W. SHAD
CL201
B W. SHAD
CL301
5.
If the lens has an extender, set the extender ON and
perform the adjustment of step 4.
3-3-14. Flare Adjustment
Object:
Grayscale chart
Equipment:
Waveform monitor
Preparation:
. OUTPUT/DL/DCC + switch: CAM/DCC +
. Select a large lens iris and shoot the grayscale chart
. Select a large lens iris and shoot the grayscale chart
covering fully the underscanned frame.
(Refer to Section 3-1-4.)
Test point:
VIDEO OUT connector
Adjustment Procedure
1.
SERVICE menu “PAGE 3”
→
R FLARE: x
G FLARE: 5
B FLARE: x
G FLARE: 5
B FLARE: x
n
Make sure that “G FLARE” is “5”.
Make sure that “G FLARE” is “5”.
2.
Push the WHT/BLK switch in the “BLK” direction to
make a black balance.
3.
Adjust the lens iris to bring the white level to A = 100
IRE.
4.
With the W. BAL switch set to “A”, push the WHT/
BLK switch in the “WHT” direction to make a white
balance.
5.
Make the lens iris large by two steps.
6.
Adjust the flare with UP and DOWN switches
alternatively to minimize the carrier leakage level.
alternatively to minimize the carrier leakage level.
3-3. Camera Adjustment
CL101
CL201
CL301
1
2
3
4
5
6
E
F
G
H
VA-169 board (B side) (DXC-D35/D35P)
VA-185 board (B side) (DXC-D35WS/D35WSP)
VA-185 board (B side) (DXC-D35WS/D35WSP)