Sony DXC-D35 User Manual
3-18
DXC-D35/D35WS(UC)
DXC-D35P/D35WSP(CE) V1
3-4. Changing the Standard Setting
Values (Video Level)
When changing the setting of black level, flare, gamma,
manual knee and white clip by the user’s desire, perform
the procedures below.
manual knee and white clip by the user’s desire, perform
the procedures below.
3-4-1. Setting Status before Changing the
Setting.
.....
Side Panel
GAIN switch:
LOW (0 dB)
OUTPUT/DL/DCC
+:
CAM/DCC
+
WHITE BAL switch:
A
ZEBRA switch:
OFF
HYPER GAIN switch:
OFF
SET UP switch:
STD
EZ MODE button:
OFF
A.IRIS MODE:
STD
ATW button:
OFF
.....
Front Panel
FILTER control:
1 (3200 K)
SHUTTER switch:
OFF
.....
Lens
IRIS:
M (Manual)
ZOOM:
M (Manual)
3-4-2. Changing the Setting Value of Black
Level
Equipment:
Waveform monitor
Test point:
VIDEO OUT connector
Procedure for changing the setting
1.
Set the lens iris to the close position (C).
2.
Push the WHT/BLK switch in the “BLK” direction to
make a black balance.
make a black balance.
3.
SERVICE menu “PAGE 15”
→
M.BLACK:
4.
Set the black level A with the UP or DOWN
switch.
M.BLACK Standard setting value = 2070 (for NTSC)
2075 (for PAL)
3-4. Changing the Standard Setting Values (Video Level)