Sony DXC-D35 User Manual

Page of 122
3-18
DXC-D35/D35WS(UC)
DXC-D35P/D35WSP(CE) V1
3-4. Changing the Standard Setting
Values (Video Level)
When changing the setting of black level, flare, gamma,
manual knee and white clip by the user’s desire, perform
the procedures below.
3-4-1. Setting Status before Changing the
Setting.
.....
Side Panel
GAIN switch:
LOW (0 dB)
OUTPUT/DL/DCC 
+:
CAM/DCC 
+
WHITE BAL switch:
A
ZEBRA switch:
OFF
HYPER GAIN switch:
OFF
SET UP switch:
STD
EZ MODE button:
OFF
A.IRIS MODE:
STD
ATW button:
OFF
.....
Front Panel
FILTER control:
1 (3200 K)
SHUTTER switch:
OFF
.....
Lens
IRIS:
M (Manual)
ZOOM:
M (Manual)
3-4-2. Changing the Setting Value of Black
Level
Equipment:
Waveform monitor
Test point:
VIDEO OUT connector
Procedure for changing the setting
1.
Set the lens iris to the close position (C).
2.
Push the WHT/BLK switch in the “BLK” direction to
make a black balance.
3.
SERVICE menu “PAGE 15”
 M.BLACK:
4.
Set the black level A with the UP   or DOWN 
switch.
M.BLACK Standard setting value = 2070 (for NTSC)
2075 (for PAL)
3-4. Changing the Standard Setting Values (Video Level)