Basic Settings with the Subdisplay
  Chapt
er
 3
   
B
a
s
ic
 A
d
jus
tment
s
 and Se
tt
ing
s
Lens file selection page
On the first line, select the number of the lens file.
On the second line, the lens-file name corresponding to the 
selected file is displayed.
The selected lens file will be retained until a new lens file 
is selected. As long as the same lens is used, further 
selection of the lens file is not required.
All the lens files are named “No Offset,” with all zero 
settings at shipment. File registration and modification of 
data in a lens file must be performed in Custom mode.
3-2-8 Confirmation of the Time Code 
and Tape Remaining
When the SRW-1 HD Portable Digital Recorder is attached 
to this camera, the time code of the recorder and 
approximate tape remaining (unit: minutes) can be 
confirmed on the subdisplay.
Time code/tape remaining display page
The time code is displayed on the first line, and the 
approximate tape remaining is displayed on the second 
line, in the range of 1 to 99 min.
Time code that is displayed on the first line
The type of the displayed time code data is linked with the 
SRW-1. Select the type of the displayed time code data on 
the SRW-1.
3-2-9 Confirmation of the Power 
Voltage and Selection of Fan 
Operation Mode
The values in voltage of the power sources connected to 
the camera can be confirmed on the subdisplay.
On the same page, the operation mode of the built-in fans 
can also be selected.
Voltage confirmation/Fan Operation mode select 
page
At 1 and 2 on the first line, the values in voltage of the 
12-V and 24-V power systems are displayed, respectively. 
If power is not supplied, “- -” is displayed.
If the voltage falls to the NEAR END level, the indication 
starts flashing. If the voltage falls further down to the END 
level, the indication flashes rapidly.
The NEAR END and END levels can be set on the <BATT 
ALARM SET> page of the MAINTENANCE menu.
Selecting Fan Operation mode
On the second line, the operation mode of the built-in fans 
can be changed according to the ambient temperature or 
the operation mode of the recorder.
Note
Indication
Meaning
TCR 00:00:00:00 Time code data of the LTC reader
TCR 00:00.00:00 Time code data of the LTC reader (DF)
TCR.00:00:00:00 Time code data of the VITC reader
UBR 00 00 00 00 User bit data of the LTC reader
UBR.00 00 00 00 User bit data of the VITC reader
TCG 00:00:00:00 Time code data of the time code 
generator
TCG 00:00:00.00 Time code data of the time code 
generator (DF)
UBG 00 00 00 00 User bit data of the time code 
generator
CTL -0:00:00:00 Data of the CTL counter
LENS:1         
No Offset
TCR 00:00:00:00
20min
T*R 00:00:00:00 Time code cannot be read with the 
LTC reader.
U*R 00 00 00 00 User bit cannot be read with the LTC 
reader.
T*R.00:00:00:00 Time code cannot be read with the 
VITC reader.
U*R.00 00 00 00 User bit cannot be read with the VITC 
reader.
Indication
Meaning
11.4V   24.1V  
FAN:AUTO1
1
2