Pelco FR106011 User Manual

Page of 40
30
C2649M (9/07)
Troubleshooting
LED indicators on the front panel of the FT106011 transmitter/FR106011 receiver (refer to Figure 2) 
allow you to monitor signal status, laser status, data activity, contact closure activation, and operating 
power. Table F provides information about the front-panel indicators and associated troubleshooting 
guidelines.
Table F.  Troubleshooting with Front-Panel Indicators
Indicator Color
Meaning
Possible Cause
Corrective Action
Power LED (Pelco badge)
Blue
Power is being applied 
to the module.
No action required.
Not lit
Power is not being 
applied to the module.
Power connection is 
faulty.
Check power connection. 
If module is rack mounted, 
reseat module or power 
supply as necessary.
Power supply has failed.
Replace power supply.
Loss of power occurs due 
to tripped circuit 
breaker(s), blown fuse(s), 
or faulty electrical 
service.
Check circuit breaker(s), 
fuse(s), or electrical service 
as necessary.
Contact Closure LED (
)
Amber
Contact is closed.
No action required.
Not lit
Contact is open.
No action required.
Connections are faulty.
Check connections.
(Continued on next page)