Sony BRC-H700 User Manual

Page of 66
14
Location and Function of Parts
5.1.2 BRC-Z700  
Rear
VISCA RS-422 connector
75 Ω termination switch
This switch is used when an external sync signal 
is utilized. Set it to OFF when this camera is in 
the middle of a daisy-chain connection of 
multiple cameras. Set it to ON when the      
camera is at the end of a daisy-chain          
connection or when nothing is connected to 
the EXT SYNC IN connector on the camera.
DATA MIX switch
Set the switch to ON to overlap the menu with 
the video signal output from the installed 
interface board. Set it to OFF not to overlap the 
menu.
Remote sensor
This is the sensor for the supplied IR Remote 
Commander Unit. This remote sensor does not 
function when IMGFLIP is set to ON in the 
SYSTEM menu.
IR SELECT switch
Selects the camera number when you operate 
multiple cameras with the same IR Remote 
Commander Unit.
RGB/COMPONENT connector
VISCA RS-232C IN connector
Connects to the RM-BR300 Remote Control Unit. 
When you join multiple cameras, connect it to 
the VISCA RS-232C OUT connector of the         
previous camera in the daisy chain.
RGB/COMPONENT
VISCA RS-422
1 2 3 4 5 6 7 8 9
EXT SYNC IN
VIDEO
IR SELECT
75
1   2   3
OFF
ON
DATA MIX
OFF
ON
IN VISCA
RS-232C OUT
S VIDEO
DC IN 12V
R
1  2 
3  4  5  6 
7  8  9  10  11  12  13 
Setting of the BOTTOM switches







Switch 1
 (59.94i/50i signal format selector)
Set to ON for output of 50i signal format, or OFF 
for output of 59.94i signal format.
Switch 2
 (RS-232C/RS-422 selector)
Set to ON for RS-422, or OFF for RS-232C. 
Switch 3
 (Communication baud rate selector)
Set to ON for 38400 bps, or OFF for 9600 bps.
Switch 4 
(Infrared signal output switch)
Set to ON to enable an infrared signal output, 
or OFF to disable the output.
Camera address selectors
Set the address of the camera. Normally set to 
0. With this setting, addresses are assigned to 
the cameras automatically in the connected 
order by pressing the POWER button while 
holding down the RESET button on the 
RM-BR300 Remote Control Unit. You can assign 
the camera address, 1 to 7, manually by setting 
these selectors as follows: 
Please note that the same camera address 
cannot be assigned to two or more different 
cameras. Furthermore, you must set the switches 
before you turn on camera power.
Note
Switch 4 is not used.
Camera   0 
7
address
Switch 1  OFF 
ON 
OFF 
ON 
OFF 
ON 
OFF 
ON
Switch 2  OFF  OFF 
ON 
ON 
OFF  OFF 
ON 
ON
Switch 3  OFF  OFF 
OFF 
OFF 
ON 
ON 
ON 
ON
 
 Pin No. 
Signal  Pin No. 
        Signal
 
Pr/R 
NC
 
Y/G 
10 
GND
 
Pb/B 
11 
GND
 
GND 
12 
NC
 
GND 
13 
HD-OUT
 
GND 
14 
Tri-level Sync/Bi-level VD
 
GND 
15 
NC
 
GND