Location and Function of Parts
10 
VISCA RS-232C IN connector
Connect to the RM-BR300 Remote Control Unit. 
When you join multiple cameras, connect it to 
the VISCA RS-232C OUT connector of the previ-
ous camera in the daisy chain.
VISCA RS-232C OUT connector
When you join multiple cameras, connect it to 
the VISCA RS-232C IN connector of the next 
camera in the daisy chain.
VISCA RS-422 connector
VISCA FUNCTION switches
Switch 1 
(RS-232C/RS-422 selector)
Set to ON for RS-422, or OFF for RS-232C.
Switch 2 
(Communication baud rate selector)
Set to ON for 38400 bps, or OFF for 9600 bps.
Switches 3 to 5 
(Camera address selectors)
Set the address of the camera. Normally set to 
0. With this setting, addresses are assigned to 
the cameras automatically in the connected 
order by pressing the POWER button while 
holding down the RESET button on the 
RM-BR300 Remote Control Unit. You can assign 
the camera address, 1 to 7, manually by setting 
these selectors as follows:
11 
Please note that the same camera address 
cannot be assigned to two or more different 
cameras.
Note
Switch 6 
(59.94i/50i signal format selector)
Set to ON for output of 50i signal format, or OFF 
for output of 59.94i signal format.
Please further note that you must set the switches 
before you turn on power to the multiplex unit.
Note
 
 Pin No. 
Signal  Pin No. 
        Signal
 
Pr/R 
NC
 
Y/G 
10 
GND
 
Pb/B 
11 
GND
 
GND 
12 
NC
 
GND 
13 
HD-OUT
 
GND 
14 
Tri-level Sync/Bi-level VD
 
GND 
15 
NC
 
GND 
 
Camera   0 
7
address
Switch 3  OFF 
ON 
OFF 
ON 
OFF 
ON 
OFF 
ON
Switch 4  OFF  OFF 
ON 
ON 
OFF  OFF 
ON 
ON
Switch 5  OFF  OFF 
OFF 
OFF 
ON 
ON 
ON 
ON
VISCA RS-232C IN connector
Connect to the RM-BR300 Remote Control Unit. 
When you join multiple cameras, connect it to 
the VISCA RS-232C OUT connector of the 
previous camera in the daisy chain.
5.2.2 BRU-300/300P SD Optical 
Multiplex Unit for use with the 
BRC-300/300P 
Rear
Card slot
AC IN connector
EXT SYNC IN connector
EXT SYNC OUT connector
Composite video output connector
S-VIDEO connector
VISCA RS-422 connector
VISCA FUNCTION switches
Switch 1 
(RS-232C/RS-422 selector)
Set to ON for RS-422, or OFF for RS-232C.
Switch 2 
(Communication baud rate selector)
Set to ON for 38400 bps, or OFF for 9600 bps.
Switches 3 to 5 
(Camera address selectors)
Set the address of the camera. Normally set to 
0. With this setting, addresses are assigned to 
the cameras automatically in the connected 
order by pressing the POWER button while 
holding down the RESET button on the 
RM-BR300 Remote Control Unit. You can assign 
the camera address, 1 to 7, manually by setting 
these selectors as follows: 
IN  EXT SYNC  OUT
S VIDEO
VISCA RS-232C
CAMERA
~
AC IN
IN
OUT
VISCA RS-422
FUNCTION
1
6
3  4 
7  8  9  10  11 
Please note that the same camera address 
cannot be assigned to two or more different 
cameras.
Note
Switch 6 is not used.
Camera   0 
7
address
Switch 3  OFF 
ON 
OFF 
ON 
OFF 
ON 
OFF 
ON
Switch 4  OFF  OFF 
ON 
ON 
OFF  OFF 
ON 
ON
Switch 5  OFF  OFF 
OFF 
OFF 
ON 
ON 
ON 
ON