Sony 510P User Manual

Page of 208
Cha
p
te
r 5  
 Ad
jus
tme
nt
s
 an
d Set
tings
 f
o
r Rec
o
rding
78
5-2 Adjusting the Black Balance and the White Balance
Black balance adjustment error messages
If any of the above error messages is displayed, retry the 
black balance adjustment. 
Keep pushing the AUTO W/B BAL to BLK until “-
BLACK SET-” appears after “-BLACK BALANCE-” 
appears. If the error message occurs again, an internal 
check is necessary.
For information about this internal check, refer to the 
Maintenance Manual.
Note
If the lens cable is not firmly connected to the LENS 
connector, it may not be possible to adjust the lens iris.  If 
this happens, the black balance will be incorrect.
Black balance memory
Values stored in memory are held until the black balance 
is next adjusted.
If a memory error occurs
If the error message “: STORED DATA : NG” flashes on 
the viewfinder screen when the camcorder is turned on, the 
black balance and white balance memory contents have 
been lost.
Adjust the black balance and white balance again. Contact 
your Sony representative if this message continues to 
appear even after the black balance and white balance have 
been adjusted again.
For details, refer to the Maintenance Manual.
5-2-2 Adjusting the White Balance
To automatically adjust the white balance
When you make automatic white balance adjustment, the 
adjustment value obtained is saved in memory.
Proceed as follows.
1
Set the switches and selectors as shown in the figure 
below.
If the setting of the GAIN selector or WHITE BAL 
switch is changed, a message reporting the new setting 
position appears for about 3 seconds in the setting 
change and adjustment progress message display area 
of the viewfinder screen.
2
Set the FILTER selector to suit the lighting conditions 
as follows.
For the PDW-530/530P:
Error message
Meaning
ABB : NG 
IRIS NOT 
CLOSED
The lens iris did not close; adjustment 
was impossible.
ABB : NG 
TIME LIMIT
Adjustment could not be completed 
within the standard number of attempts.
ABB : NG 
R (or G or B) : 
OVERFLOW
The difference between the reference 
value and the current value is so great 
that it exceeds the range. Adjustment 
was impossible.
FILTER selector (outer knob) setting and CC filter 
selection
FILTER selector (outer knob) 
setting
CC filter
A
Cross filter
B
3200 K
C
4300 K
D
6300 K
FILTER selector (inner knob) setting and ND filter 
selection
FILTER selector (inner knob) 
setting
ND filter
1
Clear
2
1
/
4
 ND
3
1
/
16
 ND
1) White balance setting values are stored in memory B only 
when the WHITE SWITCH <B> item is set to “MEM” on 
the FUNCTION 2 page of the OPERATION menu.
FILTER selector
GAIN selector: Set as low as 
possible.
OUTPUT/DCC 
switch: CAM
WHITE BAL 
switch: A or B 
1)