Sony 930 User Manual

Page of 203
8
Chapter 8 Connectors and Cables
165
HDC-900/950/930 Series Product Information Manual
8-8.
RCP-750/751, Remote Control Panel
8-8-1
Connector Input/Output Signals
8-8-1-1
AUX REMOTE
8-8-1-2
EXT I/O
8-8-2
 Connection Connector
Connections made with the connector panels during 
installation or service should be made with the 
connectors/complete cable assemblies specified in 
the following list, or equivalent parts.
Connector function 
Connection connector
AUX  REMOTE 
1-706-848-11 PLUG, 8P MALE 
or
CCU/CNU REMOTE 
Cable assembly (Option)
(8P, FEMALE) 
CCA-5-3 (3 m), CCA-5-10 (10 
m),
CCA-5-30 (30 m)
EXT I/O 
1-560-651-00 D-SUB 9P, 
MALE
(9P, Female) 
1-561-749-00 JUNCTION 
SHELL 9P
No.
Signal
Specifications
1
TX (+)
RCP SERIAL DATA
2
TX  (–)
3
RX (+)
CCU/CNU/AUX
SERIAL DATA
4
RX  (–)
5
TX GND
GND for TX
6
POWER (+) IN
RCP POWER, +10 V to +30 V
7
POWER (–) IN
GND for POWER
8
SPARE
C
CHASSIS GND CHASSIS GND
No.
Signal
Specifications
1
PREVIEW S1
CONTACT (X)
(Modification is required for 
some units)
2
PREVIEW S2
CONTACT (Y)
(Modification is required for 
some units)
3
SPARE I/O 
PORT 1
(CMOS LEVEL 3.3 HI ACTIVE)
Assignable
4
SPARE I/O 
PORT 2
(CMOS LEVEL 3.3 HI ACTIVE)
Assignable
5
SPARE I/O 
PORT 3
(CMOS LEVEL 3.3 HI ACTIVE)
Assignable
6
SPARE I/O 
PORT 4
(CMOS LEVEL 3.3 HI ACTIVE)
Assignable
7
SPARE I/O 
PORT 5
(CMOS LEVEL 3.3 HI ACTIVE)
Assignable
8
POWER OUT
+5V DC
9
GND
1
7
6
4
8
5
2
3
(External view)
CCU/CNU REMOTE
(8P, Female)
1
5
9
6
(External view)
(9P Female)