Sony 930 User Manual

Page of 203
7
Chapter 7 Location and Function of Parts and Controls
96
HDC-900/950/930 Series Product Information Manual
c
SYNC OUT (sync signal output) connector (BNC 
type)
Used for output of an SD composite sync signal or HD 
tri-level sync from the internal sync signal generator.
(Factory setting: SD composite sync)
d
PROMPTER connectors (BNC type)
Input a teleprompter signal to either of the two 
connectors. The input signal is output from the other 
connector as-is (loop-through output). If loop-through 
output is not used, terminate the unused connector 
with 75 ohms. If the signal used is a 1.0-Vp-p, 75-ohm 
analog signal, it may be output from the video 
camera’s PROMPTER OUT connector with a frequency 
bandwidth of 8 MHz, regardless of signal format.
RET4 (return video input 4) connector
When required, either of the PROMPTER connectors 
can be assigned for the fourth return video input 
exclusively for analog VBS signals.
e
MIC1 and MIC2 (microphone output 1 and 2) 
connectors (XLR 3-pin)
Used to output microphone signals from the video 
camera
f
 CAMERA connector (optical fiber connector)
Used to connect a video camera, using an optical fiber 
cable. All video camera signals, including power 
supply, control, video, and audio, are sent and 
received over one optical fiber cable.
Note
Dust on the connection surface of the optical fiber 
cable may result in transmission errors. When not 
connected, always keep the end covered with the 
supplied cap.
g
Expansion slot
For installation of the optional HKCU-951 SD Encoder 
Unit. When using the HKCU-953 HD Frame Rate 
Converter Unit, move the DIF board and internal RC 
board to this slot and install the HKCU-953 in the 
original DIF/RC board position.
h
INCOM/TALLY/PGM (intercom/tally/program 
audio) connector (D-sub 25-pin)
Used for input and output of intercom, tally, and 
program audio signals. Connect to the intercom/tally/ 
program audio connector of the intercom system.
i
MONI (HD-SDI monitor output) connector (BNC 
type)
The signal from the video camera can be mixed with 
skin tone gate signals and some aspect marker signal 
and output in HD-SDI format. 
Note
Mixing is set to ON or OFF using switches on the 
internal AT board or the MSU-700A/750 Master Setup 
Unit. 
j
RET1, RET2, and RET3 (return video input 1, 2, 
and 3) connectors (BNC type)
Return video input signals can be received from three 
different systems. The selection among from RET 1, 2 
and 3 is made using the camera’s return video switch. 
The type of input signal can be any of HD-SDI, SD-
component SDI, or analog VBS, and can be set using 
the switch on the internal DTX board, or using the
MSU-700A/750 Master Setup Unit. Signals of different 
types cannot be connected simultaneously.
Note
If a signal asynchronous with the HDCU-950 is 
supplied, it may affect the picture quality of return 
video.
k
MIC REMOTE (microphone remote) connector 
(D-sub 15-pin)
Using this connector, the video camera’s microphone 
amplifier gain can be set using external equipment 
such as an audio mixer, in five steps (60, 50, 40, 30, 
and 20 dB). When taping, set the volume to a level 
appropriate for the audio conditions.
Note
The microphone amplifier gain can also be set using 
switches on the internal AVP board. 
WF REMOTE (waveform monitor remote) connector
With the internal switch setting, the MIC REMOTE 
connector can be assigned for the WF REMOTE 
connector. In this case, the connector can be 
connected to the appropriate connector on a 
waveform monitor when operating the waveform 
monitor using an MSU-700A/750 Master Setup Unit or 
RCP-700- series Remote Control Panel. A recall-type 
monitor can be connected. For the recall-type monitor, 
preset a display mode on the waveform monitor, and 
then recall the mode externally.
l
RCP/CNU connector (8-pin)
Used to connect to an MSU-700A/750 Master Setup 
Unit, CNU-500/700 Camera Command Network Unit, 
or RCP-700-series Remote Control Panel via a CCA-5 
Connection Cable. Control signals are sent and 
received via this connector. When using an RCP-700- 
series unit, power is also supplied.
m
WF MODE (waveform monitor mode output) 
connector (4-pin)
Connect to the appropriate connector on a waveform 
monitor when monitoring a signal in Sequential mode. 
A sequence signal will be output when the SEQ button 
on the MSU-700A/750 Master Setup Unit or RCP-700 
Series Remote Control Panel is pressed, allowing 
simultaneous monitoring of the R, G, and B signals in 
Sequential mode. (When both the RCP and MSU are in 
use, this connector functions as the output connector 
for RCP control.)
n
AC IN (AC power supply input) connector
Use the specified power cord to connect to an AC 
power supply. The power cord can be secured to the 
HDCU-950 body using an optional plug holder.
7-4-3
Output Block - DIF Board
RC
SD SDI
OUT 1
SD SDI
OUT 2
PIX 
OUT
WF 
OUT
1
 SD SDI OUT 1 and SD SDI OUT 2 
     connectors
2
 PIX OUT connector
3
 WF OUT connector