Panasonic KX-TVP200 User Manual

Page of 380
B6 SYSTEM ADMINISTRATION—SYSTEM PARAMETER SETTINGS
Installation Manual
257
Other Parameters-Message Waiting Notification
Controls the handling of message waiting notification calls. 
To access the proper menu for Message Waiting Notification Parameter, follow the 
menu path as shown:
System Administration Top Menu-1-5-7-3
Table B-30 
Parameter
Value Range
(Default)
Description/Function
Outgoing Call 
Ports
Port No.
(1-12)
Specifies the port numbers used for the Message Waiting 
Notification Device feature. The VPS makes outgoing 
calls using the port specified in this parameter. At least 1 
port must be specified.
Message 
Waiting Lamp 
Ports
Port No.
(1-12)
Specifies the port numbers used for the Message Waiting 
Notification Lamp feature. 
The VPS turns on the Message Waiting Lamp of the 
extension using the port specified in this parameter. At 
least 1 port must be specified.
Message 
Waiting Lamp 
for Every 
Message
1. No
2. Yes
(Yes)
If set to "Yes", the VPS will turn on the Message Waiting 
Lamp of the extension each time a new message is 
recorded in the mailbox. This will occur even if the 
Message Waiting Lamp was not turned off from a 
previous message. This setting is useful when the first 
attempt is unsuccessful.
If set to "No", the VPS will turn on the Message Waiting 
Lamp for the first message only. The VPS will not turn on 
the lamp for subsequent messages until the subscriber 
has accessed the VPS to retrieve the messages stored 
there.
Max. Digits for 
Callback No.
1-48 digits
(20)
Specifies the maximum number of digits the caller can 
enter as a callback number. This number will display on 
beepers (pagers) if the "Beeper Callback No. Entry 
Mode" is enabled. 
Callback No. 
Entry Interdigit 
Time-Out
1-10 s
(5)
Sets the maximum allowable time between each digit on 
Beeper Callback No. Entry. If the caller does not enter 
any digits within the specified time, the VPS will not 
accept entry of any additional digits.