Dialing Parameters
These parameters specify how the VPS will initiate and control call transfers, setup outgoing 
calls, and control message waiting lamps on extensions. The procedure for verifying the 
correct code sequences for non-Panasonic KX-T series telephone systems is to manually 
execute the sequences from a single line telephone (SLT) with the PBX.
To access the proper menu for PBX Interface Parameters, follow the menu path as 
shown:
System Administration Top Menu-1-6-3
To access the proper menu for Dialing Parameters, follow the menu path as shown:
System Administration Top Menu-1-6-3-1
Table B-39 
Parameter
Value Range
(Default)
Description/Function
PBX Type
1. Other Manufacturers
2. KX-T Series
1. T308
2. T616
3. T1232/TA series
4. T96
5. T336
6. TD816
7. TD1232
8. TD500
9. Reserved
Specifies the type of PBX connected to the VPS. In 
the case of a Panasonic KX-T series telephone 
system, the model number should also be specified.
Note: The Dialing Parameters are set automatically 
to each PBX default value after selecting the PBX 
type except when setting "Other Manufacturers".
(Other Manufacturers)
Table B-40 
PBX Type
Other 
Manu-
facturers
KX-T series
T308
T616
T1232/
TA 
series
T96
T336
TD816/1232
TD612
TD500
Integration 
Mode
None
Inband Inband
None
Inband Inband Inband
*DPT
Inband
*DPT
Inband
Inband
Operator 
Transfer 
Sequence
FX
FTX
FTX
FTX
FTX
FTX
FTX
FX
FTX
FX