Preparing for installation
Standard 1.03
42
CallPilot
Switch and network requirements
Introduction
The information in this section will help you plan your 201i server 
installation.
Meridian 1 or Succession 1000 slot requirements
The 201i server occupies physical and electrical slots. 
Note: You can place the unit in Slot 9 of an Option11C as the unit can 
function from slots 9 and 10. Do not place the unit in slot 10. Even though 
the unit can physically fit, there is no electrical connection on the backplane 
to slot 11.
You must install the 201i server in two peripheral equipment slots as 
follows:
Switch
Slots
Meridian 1 tiered
systems
0 through 14 
Ensure that both slots have electrical backplane 
connectivity.
Option 11C
1 through 9 in any Option 11C cabinet
Option 11C Mini
A pair of consecutive slots in any cabinet
Note: You cannot install the 201i server in slots 0 or 
4 because these slots are dedicated to other cards. For 
more information about cards and slots, refer to the 
Option 11C Mini documentation.