CallPilot
Switch and network requirements
Introduction
The information in this section will help you plan your 201i server
installation.
installation.
Meridian 1 or Succession 1000 slot requirements
The 201i server occupies physical and electrical slots.
Note: You can place the unit in Slot 9 of an Option11C as the unit can
function from slots 9 and 10. Do not place the unit in slot 10. Even though
the unit can physically fit, there is no electrical connection on the backplane
to slot 11.
function from slots 9 and 10. Do not place the unit in slot 10. Even though
the unit can physically fit, there is no electrical connection on the backplane
to slot 11.
You must install the 201i server in two peripheral equipment slots as
follows:
follows:
Switch
Slots
Meridian 1 tiered
systems
systems
0 through 14
Ensure that both slots have electrical backplane
connectivity.
connectivity.
Option 11C
1 through 9 in any Option 11C cabinet
Option 11C Mini
A pair of consecutive slots in any cabinet
Note: You cannot install the 201i server in slots 0 or
4 because these slots are dedicated to other cards. For
more information about cards and slots, refer to the
Option 11C Mini documentation.
4 because these slots are dedicated to other cards. For
more information about cards and slots, refer to the
Option 11C Mini documentation.