CSB GP12120 F2 GP12120 Leaflet
Product codes
GP12120
Cells Per Unit
6
Voltage Per Unit
12
Capacity
12 Ah @ 20hr-rate to 1.75V per cell @25 (77 )
Weight
Approx. 3.67 kg(8.09 lbs)
Maximum Discharge Current
150A/180A(5sec)
Internal Resistance
Approx. 16 m
Operating Temperature Range
Nominal Operating Temperature Range
25
3 (77
5 )
Float Charging Voltage
Recommended Maximum Charging
Recommended Maximum Charging
3.6A
Current Limit
Equalization and Cycle Service
Self Discharge
Equalization and Cycle Service
Self Discharge
CSB Batteries can be stored for more than 6 months at
25 (77 ). Please charge batteries before using. For
higher temperatures the time interval will be shorter.
25 (77 ). Please charge batteries before using. For
higher temperatures the time interval will be shorter.
Terminal
F1/F2-Faston Tab187/250
Container Material
ABS(UL 94-HB/File E50263)*Flammability resistance of
(UL 94-V0/File E88637) can be available upon request.
Discharge: -15 ~50 ( 5 ~122 )
Charge: -15 ~40 ( 5 ~104 )
Storage: -15 ~40 ( 5 ~104 )
Charge: -15 ~40 ( 5 ~104 )
Storage: -15 ~40 ( 5 ~104 )
Constant Power Discharge Characteristics Unit:W (25
,77 )
Constant Current Discharge Characteristics Unit:A (25
,77 )
GP 12120
Specification
12V 12Ah
Powered by
GP 12120 is a general purpose battery up to 5 years in standby
service or more than 260 cycles at 100% discharge in cycle
service. As with all CSB batteries, all are rechargeable, highly
efficient, leak proof and maintenance free.
RA: 0812
Width (W)
Dimensions :
Unit: mm (inch)
Overall Height (H)
Container height (h)
Length (L)
100±1 (3.94±0.04)
94±1 (3.7±0.04)
151±2 (5.94±0.08)
98±1 (3.85±0.04)
F.V/Time
5MIN
10MIN
15MIN
30MIN
1HR
2HR
3HR
4HR
5HR
8HR
10HR
20HR
1.60V
51.2
33.2
23.9
13.9
8.14
4.70
3.37
2.70
2.24
1.45
1.19
0.622
1.67V
48.2
32.0
23.6
13.7
8.12
4.62
3.36
2.67
2.21
1.44
1.18
0.618
1.70V
46.3
31.6
23.3
13.6
8.09
4.61
3.32
2.63
2.18
1.43
1.17
0.613
1.75V
43.3
30.0
22.6
13.4
8.03
4.58
3.26
2.58
2.13
1.41
1.16
0.611
1.80V
38.8
28.0
21.5
13.0
7.81
4.48
3.17
2.50
2.06
1.38
1.14
0.594
1.85V
34.2
25.3
19.8
12.3
7.51
4.29
3.03
2.36
1.97
1.32
1.09
0.572
F.V/Time
5MIN
10MIN
15MIN
30MIN
1HR
2HR
3HR
4HR
5HR
8HR
10HR
20HR
1.60V
539
347
268
160
97.9
55.9
39.6
30.5
25.3
16.7
13.8
7.70
1.67V
515
342
265
159
97.7
55.6
39.3
30.4
25.2
16.6
13.7
7.63
1.70V
499
336
262
158
97.0
55.4
39.0
30.1
25.0
16.5
13.6
7.62
1.75V
462
326
256
156
96.1
54.9
38.5
29.8
24.4
16.2
13.4
7.55
1.80V
418
307
243
153
94.8
53.7
37.7
29.1
24.1
15.8
13.1
7.43
1.85V
369
280
221
144
91.6
52.6
36.3
28.2
23.3
15.5
12.7
7.24
13.5 to 13.8 VDC/unit Average at 25 (77 )
14.4 to 15.0 VDC/unit Average at 25 (77 )
CSB-manufactured
VRLA
batteries are UL-
recognized components
under UL924 and UL1989.
CSB is also certified by
ISO 9001 and ISO 14001.
ISO 9001 and ISO 14001.
(http://www.csb-battery.com)
by TUV CERT according to ISO 9001,ISO 14001.
The system of manufacturer was certified